Diffusion-weighted MR imaging of non-complicated hepatic cysts: Value of 3T computed diffusion-weighted imaging

نویسندگان

  • Yuko Nakamura
  • Toru Higaki
  • Yuji Akiyama
  • Wataru Fukumoto
  • Kenji Kajiwara
  • Yoko Kaichi
  • Yukiko Honda
  • Daisuke Komoto
  • Fuminari Tatsugami
  • Makoto Iida
  • Toshifumi Ohmoto
  • Shuji Date
  • Kazuo Awai
چکیده

PURPOSE To investigate the utility of computed 3T diffusion-weighted imaging (c-DWI) for the diagnosis of non-complicated hepatic cysts with a focus on the T2 shine-through effect. MATERIALS AND METHODS In 50 patients with non-complicated hepatic cysts we acquired one set of DWIs (b-value 0 and 1000 s/mm(2)) at 1.5T, and two sets at 3T (b-value 0 and 1000 s/mm(2), TE 70 ms; b-value 0 and 600 s/mm(2), TE 60 ms). We defined the original DWIs acquired with b = 1000 s/mm(2) at 1.5T and 3T as "o-1.5T-1000" and "o-3T-1000". c-DWIs were calculated with 3T DWI at b-values of 0 and 600 s/mm(2). c-DWI with b = 1000 and 1500 s/mm(2) were defined as "c-1000" and "c-1500". Radiologists evaluated the signal intensity (SI) of the cysts using a 3-point score where 1 = not visible, 2 = discernible, and 3 = clearly visible. They calculated the contrast ratio (CR) between the cysts and the surrounding liver parenchyma on each DWIs and recorded the apparent diffusion coefficient (ADC) with a b-value = 0 and 1000 s/mm(2) on 1.5T- and 3T DWIs. RESULTS Compared with o-1.5T-1000 DWI, the visual scores of all but the c-1500 DWIs were higher (p = 0.07 for c-1500- and p < 0.01 for the other DWIs). The CR at b = 1000 s/mm(2) was higher on o-3T-1000- than on o-1.5T-1000- (p < 0.01) but not higher than on c-1500 DWIs (p = 0.96). The CR at b = 0 s/mm(2) on 3T images with TE 70 ms was higher than on 1.5T images (p < 0.01). The ADC value was higher for 3T- than 1.5T images (p < 0.01). CONCLUSIONS Non-complicated hepatic cysts showed higher SI on o-3T-1000- than o-1.5T-1000 DWIs due to the T2-shine through effect. This high SI was suppressed on c-1500 DWIs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...

متن کامل

Evaluation of Diffusion Anisotropy and Diffusion Shape in Grading of Glial Tumors

Background: The most common primary tumors of brain are gliomas. Grading of tumor is vital for designing proper treatment plans. The gold standard choice to determine the grade of glial tumor is biopsy which is an invasive method.Objective: In this study, we try to investigate the role of fractional anisotropy (diffusion anisotropy) and linear anisotropy ...

متن کامل

Differentiation of active tumor from edematous regions of glioblastoma multiform tumor in diffusion MR images using heterogeneity analysis method

Background: Due to intrinsic heterogeneity of cellular distribution and density within diffusion weighted images (DWI) of glioblastoma multiform (GBM) tumors, differentiation of active tumor and peri-tumoral edema regions within these tumors is challenging. The aim of this paper was to take advantage of the differences among heterogeneity of active tumor and edematous regions within the gliobla...

متن کامل

3T MR imaging of postoperative recurrent middle ear cholesteatomas: value of periodically rotated overlapping parallel lines with enhanced reconstruction diffusion-weighted MR imaging.

BACKGROUND AND PURPOSE MR diagnostic of postoperative recurrent cholesteatomas is difficult. Our purpose was to compare multishot fast spin-echo periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion-weighted MR imaging (DWI) with array spatial sensitivity encoding technique (ASSET) single-shot echo-planar DWI and late postgadolinium T1-weighted MR im...

متن کامل

Applications of diffusion weighted imaging in detection of radiating pain to lower extremities

Introduction: To examine the hypothesis that diffusion weighted imaging (DWI) in lumbosacral region could reveal sciatic nerve course swelling that lead to lower extremity pain. The aim of present article was to find and evaluate the diffusion weighted coefficients (b-values) for scrutinizing sciatic nerve tract changes in lumbosacral region. Materials and methods: Lumbar area was imaged in 30...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2016