Effects of extradural block: comparison of the properties, circulatory effects and pharmacokinetics of etidocaine and bupivacaine.
نویسندگان
چکیده
Five healthy, unmedicated male volunteers, aged 19-25 yr, participated in a double-blind, crossover study. Each subject received, on separate occasions and via a catheter placed at L2, 1.5% etiodocaine HCl20 ml with adrenaline 5 mug/ml, or 0.75% bupivacaine HCl 20 ml with adrenaline 5 mug/ml for extradural analgesia. In addition, in order to calculate the absorption rate of the local anaesthetic agent, each subject received on two further occasions etidocaine HCl 75 mg and bupivacaine HCl 75 mg respectively by i.v. infusion, over a period of 10 min. Spread of sensory analgesia to four segments above and below the site of injection was faster with etidocaine (13 +/- 3 min) (mean +/- SD) than with bupivacaine (22 +/- 8 min). Two-segment regression occurred later for bupivacaine (260 +/- 57 min) than for etidocaine (180 +/- 96 min). Caudal spread of analgesia was more extensive with etidocaine than with bupivacaine. The onset of motor blockade tended to be faster with etidocaine (5.8 +/- 3.0 min), than with bupivacaine (10.0 +/- 3.5 min); regression of motor blockade by one unit was longer with etidocaine (306 +/- 103 min) than bupivacaine (238 +/- 75 min). Sudomotor block occurred earlier with etidocaine (4.0 +/- 2.1 min) than bupivacaine (13.7 +/- 4.8 min). Significant changes in cardiac stroke work and stroke volume occurred. For etidocaine these measurements remained below control values for 120-210 min after injection. The mean maximum arterial plasma concentration of etidocaine was 1.52 +/- 0.64 mug/ml, at 14 +/- 2 min and of bupivacaine was 1.35 +/- 0.63 mug/ml, achieved at 20 +/- 4 min. The systemic absorption of both drugs occurred in a biphasic pattern with a fast and slow half-life of 0.3 and approximately 8 h respectively.
منابع مشابه
Effects of concentration of local anaesthetic drugs in extradural block.
An increase in the concentration of bupivacaine from 0.5% to 0.75% and etidocaine from 1.0% to 1.5% for extradural block resulted in a more rapid onset of sensory analgesia and motor blockade, a greater frequency of adequate analgesia,a greater depth of motor block and a longer duration of sensory analgesia and motor blockade. An increase in the concentration of prilocaine from 2% to 3% failed ...
متن کاملEffects of extradural anaesthesia on human fetal blood flow in utero. Comparison of three local anaesthetic solutions.
Twenty-seven women, scheduled for elective Caesarean section under extradural anaesthesia were allocated randomly to one of three groups: group Ea received 1.5% etidocaine with adrenaline, group Bp 0.5% bupivacaine plain, and group Ba 0.5% bupivacaine with adrenaline. There was no difference in the quality and distribution of sensory blockade between the three groups. Motor blockade was most pr...
متن کاملChoice of local anaesthetic drug for extradural caesarean section. Comparison of 0.5% and 0.75% bupivacaine and 1.5% etidocaine.
One hundred women undergoing elective lower uterine segment Caesarean section under extradural anaesthesia received either 0.5% or 0.75% plain bupivacaine or 1.5% etidocaine with adrenaline 1:200 000 by random allocation. The time taken to establish satisfactory blockade for surgery was significantly shorter in the etidocaine group compared with either of the bupivacaine groups (P less than 0.0...
متن کاملAbsorption of bupivacaine, etidocaine, lignocaine and ropivacaine into n-heptane, rat sciatic nerve, and human extradural and subcutaneous fat.
Absorption of four amide local anaesthetics, including a new experimental agent, ropivacaine, in n-heptane, rat sciatic nerve and human extradural and subcutaneous fat was studied in vitro. The relative n-heptane/buffer (37 degrees C) partitioning of bupivacaine:etidocaine:lignocaine:ropivacaine was 10:39:1:2.9. The absorption of bupivacaine and etidocaine into nerve tissue was identified at st...
متن کاملQuality of spinal extradural anaesthesia: the influence of spinal nerve root diameter.
Profiles on the progress of spinal extradural anaesthesia were made in 246 patients using various concentrations of lignocaine, bupivacaine and etidocaine. The advance of analgesia through the different dermatomes showed a consistent and orderly spread on the upper lumbar and thoracic segments. This spread was irregular through the lower lumbar and upper sacral segments. The first sacral segmen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 48 6 شماره
صفحات -
تاریخ انتشار 1976