Bedside evaluation of respiratory distress.
نویسندگان
چکیده
Observations made at the time of the first trial of independent ventilation in 112 episodes of mechanical ventilatory support led to identification of a group of indicators, each of which, when present, was significantly associated (p less than 0.05) with a need for continued mechanical ventilation and/or with death. Six of these were potentially suitable for use in a format for clinical assessment of the risk of respiratory failure: pulse over 120 or under 70 beats per minute, respiratory rate of over 30, palpable scalene muscle recruitment in inspiration, palpable abdominal tensing in expiration, presence of irregular irregularity of respiratory rhythm with apneic pauses of varying duration, and coma or any condition preventing a patient from responding appropriately to commands aimed at producing ventilatory movements like those needed for vital capacity testing. When none of the six signs was present, there was a 90 percent chance of a favorable outcome. With one or two indicators positive, more than 50 percent of the subjects required further ventilatory support or died. There were no favorable outcomes when three or more of the signs were present together.
منابع مشابه
Clinical Monitoring with Fuzzy Automata
In this paper, a framework for an intelligent bedside monitor is presented. The monitor derives an abstraction of the current status of a patient by fuzzy state transitions on pre-processed input continuously supplied by clinical instrumentation. So far, an implementation called DIAMON-1 has been used for off-line evaluation of data of patients suffering from the adult respiratory distress synd...
متن کاملBedside lung ultrasound in emergency (BLUE) protocol: a suggestion to modify.
In the article by Lichtenstein et al (July 2008), 1 the authors describe the use of lung ultrasound in evaluating patients with acute respiratory failure. The algorithmic approach Bedside Lung Ultrasound in Emergency, the BLUE protocol, is described with a diagnostic accuracy of 90.5%. Three hundred and one consecutive patients with acute respiratory failure were assessed; 260 were included (ca...
متن کاملBedside Ultrasonography versus Brain Natriuretic Peptide in Detecting Cardiogenic Causes of Acute Dyspnea
INTRODUCTION Acute dyspnea is a common cause of hospitalization in emergency departments (ED).Distinguishing the cardiac causes of acute dyspnea from pulmonary ones is a major challenge for responsible physicians in EDs. This study compares the characteristics of bedside ultrasonography with serum level of blood natriuretic peptide (BNP) in this regard. METHODS This diagnostic accuracy study ...
متن کاملComparative diagnostic performances of auscultation, chest radiography, and lung ultrasonography in acute respiratory distress syndrome.
BACKGROUND Lung auscultation and bedside chest radiography are routinely used to assess the respiratory condition of ventilated patients with acute respiratory distress syndrome (ARDS). Clinical experience suggests that the diagnostic accuracy of these procedures is poor. METHODS This prospective study of 32 patients with ARDS and 10 healthy volunteers was performed to compare the diagnostic ...
متن کاملIterative integral parameter identification of a respiratory mechanics model
BACKGROUND Patient-specific respiratory mechanics models can support the evaluation of optimal lung protective ventilator settings during ventilation therapy. Clinical application requires that the individual's model parameter values must be identified with information available at the bedside. Multiple linear regression or gradient-based parameter identification methods are highly sensitive to...
متن کاملEvaluation of Serum NT-Pro Brain Natriuretic Peptide Levels in Neonates with Respiratory Distress
Background Respiratory Distress (RD) is a life-threatening respiratory failure. This study aimed to evaluate the diagnostic value of N-terminal prohormone of brain natriuretic peptide (NT-pro-BNP) in distinguishing respiratory and heart diseases in neonates. Materials and Methods Hundred fifty neonates aged 2-3 days randomly collected from those who hospitalized in the related ward of the Ali ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 85 2 شماره
صفحات -
تاریخ انتشار 1984