Improving Analytical Tomographic Reconstructions Through Consistency Conditions

نویسندگان

  • Filippo Arcadu
  • Jakob Vogel
  • Marco Stampanoni
  • Federica Marone
چکیده

This work introduces and characterizes a fast parameterless filter based on the Helgason-Ludwig consistency conditions, used to improve the accuracy of analytical reconstructions of tomographic undersampled datasets. The filter, acting in the Radon domain, extrapolates intermediate projections between those existing. The resulting sinogram, doubled in views, is then reconstructed by a standard analytical method. Experiments with simulated data prove that the peak-signal-to-noise ratio of the results computed by filtered backprojection is improved up to 5–6 dB, if the filter is used prior to reconstruction. Address for correspondence: [email protected] Corresponding author ar X iv :1 60 9. 06 60 4v 1 [ ph ys ic s. m ed -p h] 2 1 Se p 20 16 1002 author / short title

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An iterative projection-space reconstruction algorithm for tomography systems with irregular coverage

Most standard tomographic inversion methods require many measurements with a regular coverage of the object studied. A new method has been developed to obtain tomographic reconstructions from measurements by systems with a small number of detectors and an irregular coverage. The method reconstructs values on a regular grid in projection space from the measurements on an irregular grid by an ite...

متن کامل

Improved tomographic reconstruction of large-scale real-world data by filter optimization

In advanced tomographic experiments, large detector sizes and large numbers of acquired datasets can make it difficult to process the data in a reasonable time. At the same time, the acquired projections are often limited in some way, for example having a low number of projections or a low signal-to-noise ratio. Direct analytical reconstruction methods are able to produce reconstructions in ver...

متن کامل

Accurately approximating algebraic tomographic reconstruction by filtered backprojection

In computed tomography, algebraic reconstruction methods tend to produce reconstructions with higher quality than analytical methods when presented with limited and noisy projection data. The high computational requirements of algebraic methods, however, limit their usefulness in practice. In this paper, we propose a method to approximate the algebraic SIRT method by the computationally efficie...

متن کامل

Data and Analysis from a Time-resolved Tomographic Optical Beam Diagnostic*

An optical tomographic diagnostic instrument developed for the acquisition of high-speed time-resolved images has been fielded at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed for the creation of time histories of electron-beam cross section through the collection of Cerenkov light. Four optical lines of sight optic...

متن کامل

Three-dimensional tomographic reconstruction of mesospheric airglow structures using two-station ground-based image measurements.

A new methodology is presented to create two-dimensional (2D) and three-dimensional (3D) tomographic reconstructions of mesospheric airglow layer structure using two-station all-sky image measurements. A fanning technique is presented that produces a series of cross-sectional 2D reconstructions, which are combined to create a 3D mapping of the airglow volume. The imaging configuration is discus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Fundam. Inform.

دوره 155  شماره 

صفحات  -

تاریخ انتشار 2017