Evolution of trochlear compartment geometry in total knee arthroplasty.
نویسندگان
چکیده
BACKGROUND The study aimed to compare trochlear profiles in recent total knee arthroplasty (TKA) models and to determine whether they feature improvements compared to their predecessors. The hypothesis was that recent TKA models have more anatomic trochlear compartments and would display no signs of trochlear dysplasia. METHODS The authors analyzed the geometry of the 6 following TKA models using engineering software: PFC and Attune (DePuy), NexGen and Persona (Zimmer), Noetos and KneeTec (Tornier). The mediolateral trochlear profiles were plotted at various flexion angles (0°, 15°, 30° and 45°) to deduce the sulcus angle. RESULTS Analysis of sulcus angles reveals general convergence of recent designs towards anatomic values. At 0° of flexion, sulcus angles of recent implant models were between 156.0-157.4°, while those of previous generation models between 154.5-165.5°. At 30° of flexion, sulcus angles of recent models also lie within 145.7-148.6°, but those of previous models are between 149.5-152.0°. All three manufacturers deepened their trochlear profile at 30° of flexion in recent models compared to earlier designs. Sulcus angles converge towards anatomic values but still exceed radiologic signs of dysplasia by 2-5°. CONCLUSIONS Recent TKA designs have more anatomic trochlear geometries than earlier TKA models by the same manufacturers, but trochlear compartments still exceed radiologic signs of trochlear dysplasia by 2° to 5°. The hypothesis that recent TKA models display no signs of trochlear dysplasia is therefore refuted. Surgeons should be aware of design limitations to optimize choice of implant and extensor mechanisms alignment. LEVEL OF EVIDENCE IV geometric implant analysis.
منابع مشابه
Are current total knee arthroplasty implants designed to restore normal trochlear groove anatomy?
Biomechanical studies have shown that external rotation of the femoral TKA component improves patellar tracking but does not restore it to physiologic values. We hypothesized that this could be due to differences in the trochlear groove geometry of TKA and normal knees. This was investigated via a virtual TKA procedure that mounted femoral components on to 3-dimensional models of healthy femurs...
متن کاملMigration of a Broken Steinman Pin into the Posterior Compartment of the Leg 12 Years after Total Hip Arthroplasty
This report is on a migration of a Steinman pin into the posterior com Department of the calf. It was used to fix a greater trochanteric osteotomy in a total hip arthroplasty. The puzzling note is how this metal piece passed through the anterolateral compartment of the thigh to the posterior compartment of the calf. Accord ing to our literature review, migration of fixation pins through the kne...
متن کاملTotal knee arthroplasty using trochlear groove as guide for position of femoral component in severe knee osteoarthritis.
BACKGROUND Apart from transepicondylar axis, the native femoral sulcus was also reported to be used as a guide for the femoral component position in total knee arthroplasty (TKA). However, it was not shown in patients with severe knee osteoarthritis. This study was conducted to compare the position of trochlear groove in patients with and without osteoarthritis, and to assess whether trochlear ...
متن کاملRotational alignment of the femoral component using trochlear navigation during total knee arthroplasty: a dual-center study of 145 cases.
Rotational alignment of the femoral component during TKA is critical. Here we propose a technique using navigation of the femoral trochlea to determine the rotation of the femoral component. The rotation is considered "ideal" when the component position leads to the arthroplasty trochlea being perfectly superimposed over the native trochlea. Thus the arthroplasty trochlea will be aligned on the...
متن کاملAnalysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based Study of 449 Cases
Background: The aim of this study is to evaluate the geometry of the distal femur and the proximal tibia in the osteoarthritic knee using 3D reconstructive CT scan imaging. Methods: 449 patients with knee osteoarthritis were treated surgically in our center with patient-specific technology total knee arthroplasty. Preoperatively, all the patients underwent a CT scan according to a standard ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of translational medicine
دوره 4 1 شماره
صفحات -
تاریخ انتشار 2016