Experimental Study of Closed System in the Chlorine Dioxide-Iodide-Sulfuric Acid Reaction by UV-Vis Spectrophotometric Method

نویسندگان

  • Na Li
  • Laishun Shi
  • Xiaomei Wang
  • Fang Guo
  • Chunying Yan
چکیده

The mole ratio r(r = [I(-)](0)/[ClO(2)](0)) has great influence on ClO(2)-I(-)-H(2)SO(4) closed reaction system. By changing the initiate concentration of potassium iodide, the curve of absorbance along with the reaction time was obtained at 350 nm and 297 nm for triiodide ion, and 460 nm for iodine. The changing point of the absorbance curve's shape locates at r = 6.00. For the reaction of ClO(2)-I(-) in the absence of H(2)SO(4), the curve of absorbance along with the reaction time can be obtained at 350 nm for triiodide ion, 460 nm for iodine. The mole ratio r is equal to 1.00 is the changing point of the curve's shape no matter at which wavelength to determine the reaction. For the reaction of ClO(2)-I(-)-H(+) in different pH buffer solution, the curve of absorbance along with the reaction time was recorded at 460 nm for iodine. When r is greater than 1.00, the transition point of the curve's shape locates at pH 2.0, which is also the point of producing chlorite or chloride for chlorine dioxide at different pH. When r is less than 1.00, the transition point locates at pH 7.0.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chlorine Dioxide-Iodide-Methyl Acetoacetate Oscillation Reaction Investigated by UV-Vis and Online FTIR Spectrophotometric Method

In order to study the chemical oscillatory behavior and mechanism of a new chlorine dioxide-iodide ion-methyl acetoacetate reaction system, a series of experiments were done by using UV-Vis and online FTIR spectrophotometric method. The initial concentrations of methyl acetoacetate, chlorine dioxide, potassium iodide, and sulfuric acid and the pH value have great influence on the oscillation ob...

متن کامل

Spectrophotometric Simultaneous Kinetic Determination of Iodide and Iodate Using Partial Least-Squares Calibration Method in a Single Kinetic Run

A rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (PLS) using original and derivate data named as absorbance and rate data. The method is based on the catalytic effect of the cited anions on the reaction rate between Ce(IV) and As(III) in 2 mol l?1 sulfuric acid medium. The ...

متن کامل

Sub-ppm determination of uric acid using a sensitive kinetic-catalytic reaction system

A sensitive and selective kinetic-spectrophotometric method was developed for the determination of trace amounts of uric acid. The method is based on the inhibitory effect of uric acid on the oxidation of Janus Green by bromate in the presence of sulfuric acid. The reaction was followed spectrophotometrically by measuring the absorbance at 518 nm using the fixed-time method. Under optimum exper...

متن کامل

Response Surface Methodology in Spectrophotometric Determination of Formaldehyde Using Ch romotropic Acid

Formaldehyde in small quantities is commonly analyzed by spectrophotometric methods. One of the most-commonly used spectrophotometric techniques for this purpose is based on the reaction with chromotropic acid. Because of its simplicity, sensitivity, selectivity and its low cost, it is still widely used. Investigations for replacing the concentrated sulfuric acid with other acids or using more ...

متن کامل

Determination of ultra trace amount manganese (II) in water samples with the 1-(2-PyridylAzo)-2-Naphthol, (PAN) by the bromate ion in sulfuric acid with kinetic spectrophotometric method

A new kinetic spectrophotometic method for the determination of trace amount manganese(II) in Tea real samples has been described based on it s the catalytic effect on the oxidations of 1 - (2 – Pyridyl Azo) - 2 - Naphthol, (PAN), by potassium bromated in sulfuric acid. The reaction is followed spectrophotometrically by measuring the decrease in the absorbance at 547.5 nm. Under the optimum con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2011  شماره 

صفحات  -

تاریخ انتشار 2011