Mechanical property assessment of tissue-mimicking phantoms using remote palpation and optical read-out for amplitude of vibration and refractive index modulation.

نویسندگان

  • C Usha Devi
  • R S Bharat Chandran
  • R Mohan Vasu
  • Ajay K Sood
چکیده

A coherent light beam is used to interrogate the focal region within a tissue-mimicking phantom insonified by an ultrasound transducer. The ultrasound-tagged photons exiting from the object carry with them information on local optical path length fluctuations caused by refractive index variations and medium vibration. Through estimation of the force distribution in the focal region of the ultrasound transducer, and solving the forward elastography problem for amplitude of vibration of tissue particles, we observe that the amplitude is directed along the axis of the transducer. It is shown that the focal region interrogated by photons launched along the transducer axis carries phase fluctuations owing to both refractive index variations and particle vibration, whereas the photons launched perpendicular to the transducer axis carry phase fluctuations arising mainly from the refractive index variations, with only smaller contribution from vibration of particles. Monte-Carlo simulations and experiments done on tissue-mimicking phantoms prove that as the storage modulus of the phantom is increased, the detected modulation depth in autocorrelation is reduced, significantly for axial photons and only marginally for the transverse-directed photons. It is observed that the depth of modulation is reduced to a significantly lower and constant value as the storage modulus of the medium is increased. This constant value is found to be the same for both axial and transverse optical interrogation. This proves that the residual modulation depth is owing to refractive index fluctuations alone, which can be subtracted from the overall measured modulation depth, paving the way for a possible quantitative reconstruction of storage modulus. Moreover, since the transverse-directed photons are not significantly affected by storage modulus variations, for a quantitatively accurate read-out of absorption coefficient variation, the interrogating light should be perpendicular to the focusing ultrasound transducer axis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry

In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...

متن کامل

Optical Clearance Effect Determination of Glucose by near Infrared Technique: an Experimental Study Using an Intralipid Based Tissue Phantom

The present paper describes the results of experimentation, carried out on intra-lipid phantom to study the optical clearing properties of glucose. For this intra lipid phantom with different concentration of dextrose levels have been used and the measurement based on selected mathematical parameters have been obtained using indigenously designed amplitude modulated ultrasound & infrared system...

متن کامل

Optical palpation: optical coherence tomography-based tactile imaging using a compliant sensor.

We present optical palpation, a tactile imaging technique for mapping micrometer- to millimeter-scale mechanical variations in soft tissue. In optical palpation, a stress sensor consisting of translucent, compliant silicone with known stress-strain behavior is placed on the tissue surface and a compressive load is applied. Optical coherence tomography (OCT) is used to measure the local strain i...

متن کامل

Dispersion and Nonlinearity in Ultra-Optical Ga2O3 and TiO2-Bi2O3-PbO Glass Systems

Dispersion, as the characteristic variation of refractive index with wavelength, is more pronounced, where the wavelength is approaching to the absorption band. In ultra-optical glasses, the nonlinear refractive index, concerning to the light intensity dependent phenomenon, becomes considerable. Here, two ultra-optical property glass systems; TiO2-Bi2O3-PbO (TBP...

متن کامل

Quadrature Amplitude Modulation All Optical Orthogonal Frequency Division Multiplexing-dense Wavelength Division Multiplexing-optical Wireless Communication System under Different Weather Conditions

This paper proposes an analytical model for evaluating the performance of dense wavelength division multiplexing (DWDM) for all optical orthogonal frequency division multiplexing (AO-OFDM) optical wireless channel. The investigated performance for proposed system is evaluated for the parameters  bit error rate (BER) and Q factor .The constellation diagrams, and bit error rate (BER) of the recei...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2007