Continuous, short-interval redox data loggers: verification and setup considerations.

نویسندگان

  • C Shoemaker
  • R Kröger
  • B Reese
  • S C Pierce
چکیده

Reduction-oxidation or redox potential is typically collected by measuring redox at a single time interval and returning to the electrode to collect subsequent intervals to generate a temporal gradient of changes in redox. Typically, intervals between sampling are on the scale of hours, days, and weeks, rather than one, five, or 20 minutes due to logistical constraints of collection. These constraints are labor (i.e., constant measurements 24/7) and technology driven (i.e., construction of a unit that is capable of accurately and precisely measuring redox at fine temporal scales). This study describes a continuous, short interval redox data logger that is capable of measuring ±10 mV at minute time intervals. To ensure quality assured and quality controlled data, the redox unit was subjected to tiered verification procedures that documented hardware and probe sensitivity to changes in voltage. Furthermore, the setup was laboratory tested against known mV redox solutions (Zobel, 225 mV), flooded in soil medium over 48 h, and subjected to drying over 48 h. Results highlight and verify the accuracy and precision of the redox probes and hardware for measuring stability and changes in redox. Future research will investigate field operations of redox probes and create spatially and temporally detailed investigations to changes in redox as a result of vegetation, flooding, and management.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous Monitoring of Soil Redox Potential to Compare Layouts for Post-Rice Crops

The effect of different bay layouts (beds vs flat) on crop growth was investigated using continuous monitoring of redox potentials to explain soil O2 and nutrient (N and P) availability. Paddy rice typically leaves the soil in an anaerobic and water-logged state with low or negative redox potential. These conditions transform nutrients in the soil: free nitrate is reduced to di-nitrogen gas, an...

متن کامل

Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy

Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...

متن کامل

Comparison of the Effect of Continuous and Interval Aerobic Training on Electrocardiogram of Active Young Girls

Aims Few studies have examined the effects of various models of aerobic training on electrocardiogram (ECG). The purpose of this study was to compare the effect of continuous and interval aerobic training on ECG of active young girls.  Methods & Materials The research method was quasi-experimental and 30 active young girls were selected from among physical education students (age=17.0±0.4 yr) ...

متن کامل

A multistep continuous flow synthesis machine for the preparation of pyrazoles via a metal-free amine-redox process† †Raw spectra can be found at https://www.repository.cam.ac.uk/handle/1810/252343. ‡ ‡Electronic supplementary information (ESI) available. See DOI: 10.1039/c5re00082c Click here for additional data file. Click here for additional data file.

A versatile multistep continuous flow setup is reported for the four-step conversion of anilines into pyrazole products. The synthesis machine incorporates the use of amine-redox chemistry through diazotization and a metal-free vitamin C mediated reduction. The machine can be used for the synthesis of an array of analogues or the scale up of an individual target.

متن کامل

Inter-pulse Interval Affects the Size of Single-pulse TMS-induced Motor Evoked Potentials: a Reliability Study

Introduction: Measuring the size of motor evoked potentials (MEPs) induced by transcranial magnetic stimulation (TMS) is an investigational technique to show the level of corticospinal excitability however, some of the fundamental methodological aspects of TMS (such as the effects of inter-pulse intervals (IPI) on MEP size) are not fully understood, this issue raises concerns about the re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science. Processes & impacts

دوره 15 9  شماره 

صفحات  -

تاریخ انتشار 2013