C octanoic acid breath test
نویسنده
چکیده
Although scintigraphy, a non-invasive procedure, is usually considered to be the reference technique for measuring gastric emptying in humans, several drawbacks limit its application in routine practice. Expensive equipment is required and access to a nuclear medicine department, and the use of radioactive isotopes (generally Tc and In) can produce low but significant irradiation. It is diYcult to repeat the technique at frequent intervals or to use it with certain patients such as children or pregnant women. However, these disadvantages are not involved when stable isotopes are used. In 1993, Ghoos et al 3 were the first to report a novel technique based on the use of C octanoic acid, a medium chain fatty acid which is rapidly absorbed in the duodenum and metabolised in the liver. 5 Following oxidation, the resulting 13CO2 is excreted into breath at a level which can easily be detected and measured by isotope ratio mass spectrometry. After validation of the C octanoic breath test in healthy subjects, the same authors developed several applications, including pathophysiological and pharmacological studies. However, the test has not been validated on a large scale by other groups. Initial work of Choi et al was less promising, but a recent report from the same team did find a statistically significant correlation between scintigraphy and breath test. The purpose of the international multicentric study reported in abstract 1 was twofold: firstly, to validate the accuracy and reproducibility of the test on a large scale by reference to gastric scintigraphy, regarded as the gold standard; and secondly, to define the reference values for clinical, pharmacological, and pathophysiological studies. To facilitate comparison with the Ghoos study, the mathematical model developed by their group was used, 15 but applied to diVerent European countries including France, Italy, and Germany. Scintigraphic gastric emptying curves were calculated and fitted using a power exponential function (Weibell model) for the solid curves. Results of solid gastric emptying measurements were expressed as half emptying time (t1/2s) as previously reported by Lartigue et al. In abstract 2 a comparison was made of gastric emptying rates with and without an overnight fast and the conclusion was drawn that due to the lack of an apparent circadian rhythm, gastric emptying studies could be done at diVerent times of day. The application of the C octanoic acid breath test to study gastric emptying in the paediatric population is described in abstract 3. The non-invasive nature of the test is ideal for this age group, but further standardisation of test meals and validation of methodology is required. Abstract 4 describes a novel measurement of gastric emptying using H octanoic acid. Deuterium enters the body water pool after oxidation of the substrate and is then slowly eliminated. This method has potential for measuring gastric emptying in addition to another event by a conventional C breath test, such as fat digestion or oro-caecal transit time.
منابع مشابه
Bayesian Hierarchical Methods to Interpret the 13C-Octanoic Acid Breath Test for Gastric Emptying
BACKGROUND The (13)C-octanoic acid breath test is a convenient method for assessing gastric emptying (GE). Success depends on obtaining a well-characterized time profile of the excretion of label in breath, which may not be the case if GE is delayed. AIMS To use Bayesian techniques in conjunction with hierarchical modelling as a method to increase the success of the modelling process. METHO...
متن کاملArt. 1.1397
Principle of 13C-octanoic Acid Breath Test The rationale of 13C-octanoic acid breath test (13C-OBT) to measure gastric emptying of solids is based on (1) the firm retention of 13C-octanoic acid in the solid phase of a standard test meal during its passage through the gastric environment, followed by (2) a rapid disintegration of the solid phase in the duodenum with (3) subsequent absorption of ...
متن کاملPharmacological modulation of gastric emptying rate of solids as measured by the carbon labelled octanoic acid breath test: influence of erythromycin and propantheline.
The *C (13C or 14C) labelled octanoic acid breath test was recently developed to measure the gastric emptying rate of solids. This study aimed to investigate whether it is sensitive enough to detect pharmacologically induced changes in the gastric emptying rate. Nine healthy volunteers were studied in basal condition, after intravenous administration of 200 mg erythromycin, and after peroral ad...
متن کاملA semi-mechanistic gastric emptying pharmacokinetic model for (13)C-octanoic acid: an evaluation using simulation.
The aim of this paper is to assess the performance of a new mechanistic model for analysing (13)C-octanoic acid breath test data using simulation studies. The (13)C-octanoic acid breath test is widely used for indirect assessment of the rate of gastric emptying and it is yet to achieve universal acceptance due to inconsistencies when the results are compared with simultaneous and direct measure...
متن کاملNoninvasive (13)C-octanoic acid breath test shows delayed gastric emptying in patients with amyotrophic lateral sclerosis.
Amyotrophic lateral sclerosis (ALS) is a fatal neurodegenerative disorder characterized by progressive loss of motor neurons. However, ALS has been recognized to also involve non-motor systems. Subclinical involvement of the autonomic system in ALS has been described. The recently developed (13)C-octanoic acid breath test allows the noninvasive measurement of gastric emptying. With this new tec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1998