Development of a Compensation Scheme for a Measurement Voltage Transformer Using the Hysteresis Characteristics of a Core

نویسندگان

  • Hyewon Lee
  • Jong-Min Park
  • Kyeon Hur
  • Yong Cheol Kang
  • Frede Blaabjerg
چکیده

This paper describes the design, evaluation, and implementation of a compensation scheme for a measurement voltage transformer (VT) using the hysteresis characteristics of the core. The error of a VT is caused by the primary winding voltage and secondary winding voltage. The latter depends on the secondary current, whereas the former depends on the primary current, which is an aggregate of the exciting and secondary currents. The secondary current is obtained directly from the secondary voltage and is used to obtain the voltage across the secondary winding. For the primary current, the exciting current is decomposed into two components: core-loss and magnetizing currents. The magnetizing current is obtained by the flux-magnetizing current curve instead of the hysteresis loop to minimize the required loops for compensation. The core-loss current is obtained by dividing the primary induced voltage by the core-loss resistance. Finally, the estimated voltages across the primary and secondary windings are added to the measured secondary voltage for compensation. The scheme can significantly improve the accuracy of a VT. The results of the performance of compensator are shown in the experimental test. The accuracy of the measurement VT improves from 1.0C class to 0.1C class. The scheme can help to OPEN ACCESS Energies 2015, 8 3246 significantly reduce the required core cross section of a measurement VT in an electrical energy system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مدلسازی پدیده فرورزونانس در ترانسفورماتورها با استفاده از مدل جدید هیسترزیس هست

Based on the Preisach theory in hysteresis, this paper presents a novel transformer core model. Unlike existing mathematical-based hysteresis models, the proposed model is based on a physically correct hysteresis model and can precisely represent the actual behaviors of magnetic materials. In addition, the experimental results of a ferroresonance test of a Voltage Transformer (VT) are presented...

متن کامل

A Novel Dynamic Voltage Regulator with a Multi-level AC/AC Converter

This article proposed a novel topology of dynamic voltage regulator using transformer and PWM multi-level AC/AC converter. In this paper for finding the best value of duty ratio for switches to minimize the THD, the GA algorithm has been used and THD output voltage is assumed to be fitness function. The proposed voltage regulator employs multi-level AC/AC converter to generate compensation volt...

متن کامل

A Coordinated Control Scheme for Improving Voltage Quality Using Power Electronics Interfaced DGs

Recently, increasing of non-linear loads in the power distribution network has been increased harmonics in these networks. The harmonics problems get worse and complicated by installation of power factor correction capacitors and filters. But the Distributed Generations (DGs) interface inverters with properly control can help to improve power quality, harmonic compensation and voltage unbalance...

متن کامل

Voltage Sag in Distribution Systems- A review and comparative study (Reasons, Characteristics, Compensations and Detection)

By quick technological advancements in industrial control processes, major industries demand higher power quality. According to IEEE 1159-1995 standard, any problems in voltage, current or freq‌ue‌ncy that lead to the error or malfunctions in electrical equipment are considered as a power quality problem. Among the power quality phenomena, voltage sag has been an important problem for power sys...

متن کامل

Comparative Power Quality Analysis of Different DSTATCOM Topologies

This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015