Multipurpose conical orbital implant in evisceration.

نویسندگان

  • Harry Marshak
  • Steven C Dresner
چکیده

PURPOSE To evaluate the safety and efficacy of the porous polyethylene multipurpose conical orbital implant for use in evisceration. METHODS A retrospective review of 31 eyes that underwent evisceration and received the multipurpose conical orbital implant. The orbits were evaluated at 1 week, 1 month, and 6 months after final prosthetic fitting for implant exposure, superior sulcus deformity, and prosthetic motility. RESULTS There were no cases of extrusion, migration, or infection. All patients had a good cosmetic result after final prosthetic fitting. Prosthetic motility was good in all patients. Exposure developed in one eye (3%) and a superior sulcus deformity developed in one eye (3%). CONCLUSIONS Placement of an multipurpose conical orbital implant in conjunction with evisceration is a safe and effective treatment for blind painful eye that achieves good motility and a good cosmetic result.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term Surgical Outcomes of the Multi-purpose Conical Porous Synthetic Orbital Implant

PURPOSE We present clinical results of the use of the multipurpose conical porous synthetic orbital implant (MCOI) in surgical procedures of evisceration, enucleation, and secondary enucleation in ophthalmology patients. METHODS A retrospective review was performed of 59 eyes in which conical implants were used, including 36 cases of eviscerations, 11 enucleations, and 9 secondary enucleation...

متن کامل

Autogenous dermis-fat orbital impant for anophthalmic socket.

To our knowledge, there is no report of dermis-fat graft (DFG) implant for orbital reconstruction from Oman. We hereby presented a case report of a 10-year-old boy with a blind and painful left eye secondary to penetrating eye injury presented with implant extrusion following evisceration with a polymethyl methacrylate implant. The evisceration procedure was converted to enucleation and a DFG o...

متن کامل

Painful blind eye: efficacy of enucleation and evisceration in resolving ocular pain.

AIMS To assess the effectiveness of enucleation or evisceration in relieving pain from painful blind eyes. METHODS 24 patients with intractable ocular pain underwent enucleation or evisceration with or without an orbital implant. RESULTS Complete pain relief was achieved in all patients at an average time of 3 months (range 1-15 months). Seven patients required further medical or surgical t...

متن کامل

Treatment of Intractable Orbital Implant Exposure with Scleral Melting By Secondary Implant of Dermis Fat Graft-A Case Report

A 30 year old female with absolute glaucoma status post-evisceration developed recurrent orbital implant exposure and scleral melting. We successfully treated the large conjunctiva defect by utilizing secondary implant of dermis fat graft for tissue growth and tension-free conjunctiva closure. The patient was satisfied with the postoperative outcome, and no major complications were observed in ...

متن کامل

[Rabbit orbital measure evaluations after enucleation and evisceration].

PURPOSE To assess orbital volume in weaned rabbits, submitted to enucleation and evisceration, with orbital volume reconstitution using porous polyethylene (PP) spheres, analyzed by computed tomography, by the water displacement test and external orbital measures using Image-J software. METHODS This experimental randomized study consisted of 48 albino rabbits, with 42 days of life, submitted ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmic plastic and reconstructive surgery

دوره 21 5  شماره 

صفحات  -

تاریخ انتشار 2005