New Adaptive Hysteresis Modulation Technique for Three Phase Shunt Active Power Filter
نویسندگان
چکیده
Department of Electrical Power and Machines Faculty of Engineering Cairo University Giza, Egypt Abstract The quality of the current waveform generated by a current controlled, voltage source shunt active power filter depends basically on three factors: (i) The reference signal being generated; (ii) the modulation method used and (iii) the switching frequency of the PWM modulator. A new adaptive hysteresis band modulation method is proposed. In this paper, the periodical sampling constant hysteresis band modulation method and the proposed method are analyzed. These modulation methods are tested in switching an active power filter based on a voltage source topology, in a three phase three wire connections. They are compared in terms of THD of supply current, switching losses, and their flexibility of tuning. The simulation results demonstrate the viability and effectiveness of the new adaptive Hysteresis band modulation method in reducing the ripple, losses, and THD of supply current.
منابع مشابه
New Hysteresis Control Method for Three Phase Shunt Active Power Filter
The quality of the current waveform generated by a current controlled, voltage source shunt active power filter depends basically on three factors: (i) The reference signal being generated; (ii) the modulation method used and (iii) the switching frequency of the PWM modulator. A new adaptive hysteresis band modulation method is proposed. In this paper, the periodical sampling constant hysteresi...
متن کاملPerformance Scrutiny of Two Control Schemes Based on DSM and HB in Active Power Filter
This paper presents a comparative analysis between two current control strategies, constant source power and generalized Fryze current, used in Active Power Filter (APF) applications having three different modulation methods. The Hysteresis Band (HB) and first-order Delta-Sigma Modulation (DSM) as well as the second-order DSM is applied. The power section of the active power filter is viewed as...
متن کاملAn adaptive hysteresis band current controller for shunt active power filter
In this paper, an adaptive hysteresis band current controller is proposed for active power filter to eliminate harmonics and to compensate the reactive power of three-phase rectifier. The adaptive hysteresis band current controller, proposed by Bose [An adaptive hysteresis band current control technique of a voltage feed PWM inverter for machine drive system, IEEE Trans. Ind. Electron. 37 (5) (...
متن کاملDesing And Implementation of Adaptive Active Filters for Exact Estimation And Elimination of AC Network Distortions
In recent years, active filters have been considered and developed for elimation of harmonics in power networks. Comparing with passive, they are smaller and have better compensating characteristics and resistance to line distortions. In this paper, a novel idea based on adaptive filter theory in presented to develop an active filter to eliminate the distortions of an arbitrary signal. Using th...
متن کاملDesing And Implementation of Adaptive Active Filters for Exact Estimation And Elimination of AC Network Distortions
In recent years, active filters have been considered and developed for elimation of harmonics in power networks. Comparing with passive, they are smaller and have better compensating characteristics and resistance to line distortions. In this paper, a novel idea based on adaptive filter theory in presented to develop an active filter to eliminate the distortions of an arbitrary signal. Using th...
متن کامل