Circumferential variations of mechanical behavior of the porcine thoracic aorta during the inflation test.

نویسندگان

  • Jungsil Kim
  • Seungik Baek
چکیده

We developed an extension-inflation experimental apparatus with a stereo vision system and a stress-strain analysis method to determine the regional mechanical properties of a blood vessel. Seven proximal descending thoracic aortas were investigated during the inflation test at a fixed longitudinal stretch ratio of 1.35 over a transmural pressure range from 1.33 to 21.33 kPa. Four circumferential regions of each aorta were designated as the anterior (A), left lateral (L), posterior (P), and right lateral (R) regions, and the inflation test was repeated for each region of the aortas. We used continuous functions to approximate the surfaces of the regional aortic wall in the reference configuration and the deformed configuration. Circumferential stretch and stress at the four circumferential regions of the aorta were computed. Circumferential stiffness, defined as the tangent of the stress-stretch curve, and physiological aortic stiffness, named pressure-strain elastic modulus, were also computed for each region. In the low pressure range, the stress increased linearly with increased stretch, but the mechanical response became progressively stiffer in the high-pressure range above a transition point. At a transmural pressure of 12.00 kPa, mean values of stiffness were 416±104 kPa (A), 523±99 kPa (L), 634±91 kPa (P), and 489±82 kPa (R). The stiffness of the posterior region was significantly higher than that of the anterior region, but no significant difference was found in pressure-strain elastic modulus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Longitudinal differences in the mechanical properties of the thoracic aorta depend on circumferential regions.

Understanding the mechanical behavior of the arterial wall and its spatial variations is essential for the study of vascular physiopathology and the design of biomedical devices that interact with the arterial wall. Although it is generally accepted that the aortic wall gets stiffer along its length, the spatial variations in the mechanical behavior of the thoracic aorta are not well understood...

متن کامل

Hyperelastic behavior of porcine aorta segment under extension-inflation tests fitted with various phenomenological models.

Most of hyperelastic models for the constitutive modeling of the typical mechanical behaviour of the arterial wall tissue in literature are based on the test data from different animals and arteries. This paper is concerned with the material parameter identification of several phenomenological hyperelastic models by fitting the data from five extension-inflation tests of the porcine aorta segme...

متن کامل

High rate mechanical behaviour and failure properties of aortic tissue

While traumatic aortic rupture (TAR) continues to be a major cause of fatality in motor vehicle accidents, its underlying mechanisms at the tissue level are not well understood. During accidents, aorta may undergo high-rate large deformations and therefore, the tissue mechanical properties obtained in the physiological range cannot accurately describe the tissue behavior in such conditions. Ver...

متن کامل

Re-examination of the mechanical anisotropy of porcine thoracic aorta by uniaxial tensile tests

OBJECTIVE Considering past studies on the orthotropic anisotropy of arteries in the circumferential and axial directions, this work aims to experimentally study the anisotropic behaviour of arteries by tensioning multi-directional strips of porcine thoracic aorta. METHODS Histology is first analyzed by staining arterial sections of three orthotropic (axial, circumferential, and radial) planes...

متن کامل

Quantification of structural compliance of aged human and porcine aortic root tissues.

The structural compliance of the aortic root has a significant implication for valve procedures such as transcatheter aortic valve implantation and valve-sparing aortic root replacement. However, a detailed quantification of human aortic root structural compliance, particularly in different regions, has been incomplete. In this study, the structural properties of human aortic roots (81 ± 8.74 y...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 44 10  شماره 

صفحات  -

تاریخ انتشار 2011