Comment on Borges et al. "regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse".

نویسندگان

  • Niels Christian Hellige
  • Günter Hahn
  • Gerhard Hellige
چکیده

TO THE EDITOR: The paper by Borges et al. (1) presents an excellent experimental study comparing two approaches for the evaluation of regional pulmonary perfusion by electrical impedance tomography (EIT) with single photon emission computerized tomography (SPECT) as well established reference method. The negative results on the pulsatility approach confirm the skepticism addressed by recently published papers (3, 5, 6), which point out that there are many sources of error in evaluating cardiac-related impedance changes as blood flowrelated signals. On the other hand, the data obtained by impedance indicator dilution are in good agreement with the perfusion distributions acquired by SPECT. However, related to the evaluation of the indicator dilution curves as well as to the application of 20% sodium chloride solution (NaCl) the following comments are indispensable. 1) Evaluation of indicator dilution curves. The passage of the indicator bolus is recorded as a decrease of impedance because NaCl increases the ion content and hereby raises conductivity of the blood. The authors describe in section Concept of Estimating Regional Lung Perfusion by EIT that for evaluation they are “inverting these curves (multiplying by 1)”. To demonstrate the “negative perturbation caused by the hypertonic bolus” in Fig. 1, noninverted dilution curves and corresponding fitted gamma functions are presented. This procedure is questionable because there is no linear correlation between indicator concentration time course and resistivity changes. Increasing sodium chloride concentration causes fairly proportional increase of conductivity that, however, is inverse to resistivity change (conductivity 1/ resistivity). This matters that evaluation of the dilution curves recorded by EIT as impedance changes implies underestimations that increase with rising indicator concentration changes. The authors should discuss this issue in relation to the presented evaluation procedure and the resulting data. 2) Use of a 20% sodium chloride solution as indicator. The authors refer the use of hypertonic indicator solution to the 1992 publication of Brown et al. (2), who, however, applied an isotonic 0.9% NaCl solution. About 10 years later the usage of a 5.8% solution in animals was published (4). The actually utilized 20% solution is extremely hypertonic exhibiting an osmolarity of 7,000 mosM and a sodium concentration of 3,500 meq/l compared with 300 mosM respectively 140 meq/l in normal blood. The hyperosmolarity will cause major water shift and changes of resistance in pulmonary circulation. The appearance of the high sodium bolus in the coronary circulation after lung passage might be dangerous in patients in view of cardiac contractility and electrophysiology. Ionic x-ray contrast media such as diatrizoates with osmolarity of 2,100 mosM and sodium content of 157 meq/l today in most countries are out of use for angiography because of marked side effects. Borges et al. conclude that they “describe a novel method based on EIT for estimating regional lung perfusion at the bedside.” This statement suggests a direct transferability of the method in clinical use. The safety of the used NaCl solution on patients should be critically reconsidered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse.

The assessment of the regional match between alveolar ventilation and perfusion in critically ill patients requires simultaneous measurements of both parameters. Ideally, assessment of lung perfusion should be performed in real-time with an imaging technology that provides, through fast acquisition of sequential images, information about the regional dynamics or regional kinetics of an appropri...

متن کامل

Regional Lung Perfusion estimated by Electrical Impedance 1 Tomography in a piglet model of lung collapse 2 3

42 43 The assessment of the regional match between alveolar ventilation and perfusion in 44 critically ill patients requires simultaneous measurements of both parameters. Ideally, 45 assessment of lung perfusion should be performed in real-time with an imaging 46 technology which provides, through fast acquisition of sequential images, information 47 about the regional dynamics or regional kine...

متن کامل

Hyperoxia affects the regional pulmonary ventilation/perfusion ratio: an electrical impedance tomography study.

BACKGROUND The way in which hyperoxia affects pulmonary ventilation and perfusion is not fully understood. We investigated how an increase in oxygen partial pressure in healthy young volunteers affects pulmonary ventilation and perfusion measured by thoracic electrical impedance tomography (EIT). METHODS Twelve semi-supine healthy male volunteers aged 21-36 years were studied while breathing ...

متن کامل

Fuzzy Modeling of Electrical Impedance Tomography Images of the Lungs

OBJECTIVES Aiming to improve the anatomical resolution of electrical impedance tomography images, we developed a fuzzy model based on electrical impedance tomography's high temporal resolution and on the functional pulmonary signals of perfusion and ventilation. INTRODUCTION Electrical impedance tomography images carry information about both ventilation and perfusion. However, these images ar...

متن کامل

Literature List Electrical Impedance Tomography

Breathing moves volumes of electrically insulating air into and out of the lungs, producing conductivity changes which can be seen by electrical impedance tomography. It has thus been apparent, since the early days of EIT research, that imaging of ventilation could become a key clinical application of EIT. In this paper, we review the current state and future prospects for lung EIT, by a synthe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 112 12  شماره 

صفحات  -

تاریخ انتشار 2012