Prolonged use for at least 10 days of intraaortic balloon pumping (IABP) for heart failure.

نویسندگان

  • Kiyohiro Oshima
  • Yasuo Morishita
  • Hiroshi Hinohara
  • Yuji Kadoi
  • Yoshiro Hayashi
  • Yukio Tajima
  • Fumio Kunimoto
چکیده

Intraaortic balloon pumping (IABP) is a useful therapy for refractory heart failure. However, the safe duration of this therapy and possible complications due to long-term IABP support remain unclear. In this study, we reviewed retrospectively patients requiring the long-term use of IABP, defined here as 10 days or more, to estimate the background and prognosis of patients undergoing long-term use of IABP. The characteristics and perioperative status were compared between survivors and nonsurvivors. A total of 18 patients including 12 males and 6 females required long-term IABP use. IABP was induced in 13 patients (72%) following cardiac surgery and in 5 without cardiac surgery. The mean duration of IABP support was 17 +/- 7 days. Seven patients survived and 11 died of heart failure and/or associated other organ failure. Multiple organ failure (MOF) was recognized in 10 patients, and the incidence of MOF was significantly (P = 0.005) lower in the survivors (14%) compared to the nonsurvivors (82%). The percentage of postcardiac surgery patients was also significantly (P = 0.027) higher in nonsurvivors (91%) than in survivors (43%). Logistic regression analysis identified MOF and cardiac surgery as independent predictors for death. Femoral arterial-venous fistula was the only IABP-related complication. In patients receiving long-term IABP, attention should be paid to other organ complications associated with heart failure, and the use of other circulatory supports such as PCPS or VAD to avoid MOF should be considered if necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shock.

BACKGROUND AND AIM Despite major advances in the treatment of heart failure, cardiogenic shock (CGS) remains associated with substantial mortality. Recent data suggest that the TandemHeart percutaneous ventricular assist device (pVAD) may be useful in the management of CGS. The aim of this prospective randomized study was to test the hypothesis that the TandemHeart (pVAD) provides superior hemo...

متن کامل

Tako-tsubo cardiomyopathy complicated by QRS prolongation.

A 68-year-old woman was admitted to our hospital due to sudden onset of dyspnea. On admission, electrocardiogram (ECG) showed T-wave inversion and QRS prolongation (120 msec) that were not found in her previous ECG. Chest X-ray showed pulmonary edema and cardiac enlargement. Left ventriculogram showed akinesis of the left ventricle except in the basal region. No significant coronary stenosis wa...

متن کامل

Miniature intracardiac assist device provides more effective cardiac unloading and circulatory support during severe left heart failure than intraaortic balloon pumping.

BACKGROUND Hemodynamic assistance with a miniature intracardiac pump may fill the treatment gap between use of an intraaortic balloon pump (IABP) and the current, more invasive ventricular assist devices. The objective of this study was to compare the hemodynamic efficacy of a miniature intracardiac pump device with that of IABP. METHODS AND RESULTS Reversible acute mitral regurgitation (AMR)...

متن کامل

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

Elective versus provisional intraaortic balloon pumping in unprotected left main stenting.

BACKGROUND Elective intraaortic balloon pump (IABP) may reduce acute complications during unprotected left main (ULM) stenting. However, few data exist on criteria for elective IABP support during ULM stenting. METHODS Since January 1993, 219 consecutive patients underwent elective ULM stenting: 69 had elective IABP support (elective IABP group), whereas 150 patients had conventional procedur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International heart journal

دوره 46 6  شماره 

صفحات  -

تاریخ انتشار 2005