Exact inversion of the exponential x-ray transform for rotating slant-hole (RSH) SPECT.

نویسندگان

  • J M Wagner
  • F Noo
  • R Clackdoyle
چکیده

The RSH SPECT scanner provides parallel-beam attenuated projections for a fully 3D acquisition geometry. The geometry can be represented by circles on the unit sphere of projection directions, one circle for each position of the detector head. Unlike most other fully 3D geometries this one is particularly challenging because there are no 2D subsets in the data. When no attenuation is present, it is well known that an unmeasured projection can be synthesized if it lies inside one of the measured circles. The main result of this work is that under some assumptions on the attenuation distribution, attenuated projections within a circle can be synthesized from available attenuated projections. One consequence is that RSH SPECT projections can be rebinned into a conventional SPECT geometry for which analytic attenuation correction techniques are available.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3-D image reconstruction from exponential X-ray projections using Neumann series

In two dimensions, the exponential X-ray transform has been wellstudied due to its applications of correcting attenuation effects in Single Photon Emission Computed Tomography (SPECT). Explicit inversion formulas have been known for over 15 years. The threedimensional (3D) case has not been as thoroughly examined, and inversion formulas are available for only a few of the wide range of possible...

متن کامل

The evaluation of slant hole collimator in myocardial perfusion SPECT: a simulation study

Introduction: We have investigated cardiac SPECT with slant hole collimator in which the holes are slanted towards the target organ, to provide greater sensitivity over the parallel hole collimator. In addition, parallel hole collimator was used to obtain a comparison in FWHM, sensitivity, Compton and photoelectric area values in the simulations. Materials and Methods...

متن کامل

Inversion of the 3D exponential x-ray transform for a half equatorial band and other semi-circular geometries.

This work presents new mathematical results on the inversion of the exponential x-ray transform. It is shown that a reconstruction formula can be obtained for any dataset whose projection directions consist of a union of half great circles on the unit sphere. A basic example of such a dataset is the semi-equatorial band. The discussion in the paper is mostly focused on this example. The reconst...

متن کامل

The inversion of the exponential Radon transform for quantitative brain SPECT.

The mathematical derivation for the inversion of the exponential Radon transform is presented and the implementation of the inversion is detailed. The inversion can be verified and implemented by the readers for practical applications, such as for quantitative reconstruction of brain SPECT (single-photon emission computed tomography).

متن کامل

Segmented slant hole collimator for stationary cardiac SPECT: Monte Carlo simulations.

PURPOSE This work is a preliminary study of a stationary cardiac SPECT system. The goal of this research is to propose a stationary cardiac SPECT system using segmented slant-hole collimators and to perform computer simulations to test the feasibility. Compared to the rotational SPECT, a stationary system has a benefit of acquiring temporally consistent projections. The most challenging issue i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 47 15  شماره 

صفحات  -

تاریخ انتشار 2002