The improvement of electrochemical detection of meloxicam is presented by modification of a glassy carbon electrode with anionic layer of cysteic acid providing electrostatic accumulation of the analyte onto the electrode surface. The modification formed by electrochemical oxidation of L-cysteine was performed by cycling potential in cysteine solution. The anodic peak current obtained at + 1.088 V (vs. Ag/AgCl) by voltammetry was linearly dependent on the meloxicam concentration in the range of 4.3 × 10 ~ 8.5 × 10 M in the B-R buffer solution (0.04 M, pH 1.86) with a correlation coefficient of 0.999. The detection limit (S/N = 3) is 1.5 × 10 M. The low-cost modified electrode shows good sensitivity, selectivity and stability and has been applied to the determination of meloxicam in pharmaceutical formulation and spiked serum with satisfactory results. The electrochemical reaction mechanism of meloxicam was discussed.
منابع مشابه
Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...
متن کاملAdsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...
متن کاملVoltammetric Determination of Cysteine (2-amino-3-mercaptopropanoic acid, CySH) by Means of 4 4'-biphenol as a Homogeneous Mediator
In the present research, 4, 4'-biphenol was used as a homogeneous mediator for determining cysteine (CySH) on a Glassy Carbon Electrode (GCE). To describe the electrochemical properties of 4,4'-biphenol and to examine its electrocatalytic impacts on cysteine oxidation, both Cyclic Voltammetry (CV) and Linear Sweep Voltammetry (LSV) were employed. Our findings revealed that 4,4'-biphenol could s...
متن کاملVoltammetric Determination of Cysteine (2-amino-3-mercaptopropanoic acid, CySH) by Means of 4 4'-biphenol as a Homogeneous Mediator
In the present research, 4, 4'-biphenol was used as a homogeneous mediator for determining cysteine (CySH) on a Glassy Carbon Electrode (GCE). To describe the electrochemical properties of 4,4'-biphenol and to examine its electrocatalytic impacts on cysteine oxidation, both Cyclic Voltammetry (CV) and Linear Sweep Voltammetry (LSV) were employed. Our findings revealed that 4,4'-biphenol could s...
متن کاملStudy and Electrochemical Determination of Tyrosine at Graphene Nanosheets Composite Film Modified Glassy Carbon Electrode
A graphene nanosheets (GNS) film coated glassy carbon electrode (GCE) was fabricated for sensitive determination of tyrosine (Tyr). The GNS-based sensor was characterized by scanning electron microscope and electrochemical impedance spectroscopy. The voltammetric techniques were employed to study electro-oxidation of Tyr. The results revealed that the modified electrode showed an electrocatalyt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006