Reduction of CSF artifacts on FLAIR images by using adiabatic inversion pulses.

نویسندگان

  • J V Hajnal
  • A Oatridge
  • A H Herlihy
  • G M Bydder
چکیده

The purpose of this study was to investigate the possibility that some artifactual high signals produced in CSF with fluid-attenuated inversion-recovery MR sequences could be due to inhomogeneity in the amplitude of the initial inversion pulse, and that this problem could be reduced or eliminated by the use of adiabatic inversion pulses. Studies with four volunteers showed dependence of high CSF signals in the posterior fossa on radiofrequency pulse amplitudes and that these signals could be eliminated by the use of adiabatic inversion pulses. Two illustrative clinical cases are included.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of imaging parameters on high-intensity cerebrospinal fluid artifacts in fast-FLAIR MR imaging.

BACKGROUND AND PURPOSE High-intensity CSF artifacts at the basal cisterns on MR images are often seen when a fast fluid-attenuated inversion recovery (FLAIR) technique is used. We investigated the influences of four optional fast-FLAIR sequence parameters on the high-intensity CSF artifacts. METHODS A total of 377 patients (age range, 1 week to 91 years; mean 40.6 years; 186 female, 191 male)...

متن کامل

Artifact simulating subarachnoid and intraventricular hemorrhage on single-shot, fast spin-echo fluid-attenuated inversion recovery images caused by head movement: A trap for the unwary.

BACKGROUND AND PURPOSE Single-shot, fast spin-echo, fluid attenuated inversion recovery (SS-FSE-FLAIR) images are frequently used to detect disease in the brain and subarachnoid space in confused or uncooperative patients who may move during the examination. In some of these patients, high signal intensity areas are seen on good-quality images in the subarachnoid space and ventricular system in...

متن کامل

Reduction of CSF and blood flow artifacts on FLAIR images of the brain with k-space reordered by inversion time at each slice position (KRISP).

BACKGROUND AND PURPOSE Our purpose was to test a new variant of the fluid-attenuated inversion-recovery (FLAIR) sequence that was designed to reduce CSF and blood flow artifacts by use of a non-slice-selective inversion pulse and k-space reordered by inversion time at each slice position (KRISP). METHODS With the KRISP FLAIR sequence, the slice order was cycled so that each inversion time (TI...

متن کامل

The low sensitivity of fluid-attenuated inversion-recovery MR in the detection of multiple sclerosis of the spinal cord.

PURPOSE To confirm the expected superiority of fluid-attenuated inversion-recovery (FLAIR) over conventional fast spin-echo MR imaging in the detection of multiple sclerosis (MS) of the spinal cord. METHODS Fifteen subjects with known MS involving the spinal cord and brain were studied prospectively. The entire cord was imaged with a phased-array coil on a 1.5-T MR system. Sagittal T1-weighte...

متن کامل

Improved Contrast and Image Homogeneity with BIR4 Pulses in Magnetization Prepared Flair at 7 Tesla

Purpose: To improve image homogeneity and contrast of 3D FLAIR images at 7T. Introduction: FLAIR images with good T2 weighting can be obtained at 7T if magnetization preparation (MP) is applied prior to inversion [1]. However, the SNR and contrast are still limited in areas where the transmit field amplitude (B1) is reduced or inhomogeneous, such as the temporal operculum, the temporal lobes an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2001