Mammographic microcalcifications: detection with xerography, screen-film, and digitized film display.
نویسندگان
چکیده
Pulverized bone specks and aluminum oxide specks were measured by hand into sizes ranging from 0.2 mm to 1.0 mm and then arranged in clusters. These clusters were superimposed on a human breast tissue phantom, and xeromammograms and screen-film mammograms of the clusters were made. The screen-film mammograms were digitized using a high-resolution laser scanner and then displayed on cathode ray tube (CRT) monitors. Six radiologists independently counted the microcalcifications on the xeromammograms, the screen-film mammograms, and the digitized-film mammograms. The xeromammograms were examined with a magnifying glass; the screen-film images were examined with a magnifying glass and by hot light; and the digitized-film images were examined by electronic magnification and image processing. The bone speck size that corresponded to a mean 50% detectability level for each technique was as follows: xeromammography, 0.550 mm; digitized film, 0.573 mm; and screen-film, 0.661 mm. We postulate that electronic magnification and image processing with edge enhancement can improve the capability of screen-film mammography to enhance the detection of microcalcifications.
منابع مشابه
A Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures
The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were ...
متن کاملComputed-aided diagnosis (CAD) in the detection of breast cancer.
Computer-aided detection (CAD) systems have been developed for interpretation to improve mammographic detection of breast cancer at screening by reducing the number of false-negative interpretation that can be caused by subtle findings, radiologist distraction and complex architecture. They use a digitized mammographic image that can be obtained from both screen-film mammography and full field ...
متن کاملScreen-Film Mammography and Soft-Copy Full-Field Digital Mammography: Comparison in the Patients with Microcalcifications
OBJECTIVE We wanted to compare the ability of screen-film mammography (SFM) and soft-copy full-field digital mammography (s-FFDM) on two different monitors to detect and characterize microcalcifications. MATERIALS AND METHODS The images of 40 patients with microcalcifications(three patients had malignant lesion and 37 patients had benign lesion), who underwent both SFM and FFDM at an interval...
متن کاملDetectors for digital mammography
Introduction Mammography is the most technically demanding radiographic modality, requiring high spatial resolution, excellent low contrast discrimination, and wide dynamic range. The development of dedicated mammography systems [1] in the mid-1960s and the refinements in film-screen technology over its long evolution [2,3] were of critical importance in establishing the benefits of mammography...
متن کاملCurrent Status of and Future Directions for Digital Mammography
─ 179 ─ Screen-film mammography has certain technical limitations which reduce its effectiveness: the film gradient must be balanced against the need for wide latitude, detection of microcalcifications and portrayal of the clarity of the margins of breast masses are reduced due to the presence of film noise in the displayed image, film processing artifacts can degrade the mammographic image, an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 162 3 شماره
صفحات -
تاریخ انتشار 1986