Diagnostic performance of PET, SPECT and CMR perfusion imaging for the detection of significant coronary artery disease - a meta-analysis

نویسندگان

  • Caroline Jaarsma
  • Tim Leiner
  • Sebastiaan Bekkers
  • Harry Crijns
  • Joachim Wildberger
  • Eike Nagel
  • Patricia Nelemans
  • Simon Schalla
چکیده

Data extraction Four reviewers screened potential studies and independently extracted study data. Discrepancies were resolved by consensus. Data synthesis Of the 3694 citations, 166 articles (17.744 patients) met the inclusion criteria: 18 PET (1.441 patients), 111 SPECT (13.462 patients) and 37 CMR (2.841 patients) articles respectively. The overall patient based analysis demonstrated a sensitivity of 0.85 (95% confidence interval [CI] 0.83-0.88), 0.88 (95% 0.88-0.89) and 0.89 (95% CI 0.88-0.91); and a specificity of 0.83 (95% CI 0.760.88), 0.60 (95% CI 0.59-0.62), 0.76 (95% CI 0.73-0.78) for PET, SPECT and MRI respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Accuracy of Gated-SPECT Myocardial Perfusion Imaging and Exercise Stress Test for Diagnosis of Coronary Artery Disease

Background and Objective:Accurate diagnosis of CAD using noninvasive procedures is of great importance. The aim of the study is to assess diagnostic accuracy of myocardial perfusion imaging and compare it with exercise stress test in order to decipher a more accurate and cost-effective method for CAD detection. Materials and Methods:Of 430 consecutive patients suspected with CAD, 104 performed...

متن کامل

Myocardial perfusion imaging in coronary artery disease: SPECT, PET or CMR?

Noninvasive imaging in the evaluation of a wide variety of cardiovascular diseases has gained an increasing role in the diagnostic strategy in current cardiology practice [1–4]. This holds in particular for patients with myocardial ischaemia due to coronary artery disease (CAD) [5–7]. Of the present imaging modalities, single-photon emission computed tomography (SPECT), positron emission tomogr...

متن کامل

The diagnostic difference between 18F- FDG PET and 99mTc-HMPAO SPECT perfusion imaging in assessment of Alzheimer's disease

Introduction:Brain imaging with F-18 fluorodeoxyglucose (18F-FDG) positron ‎emission tomography or Tc-99m hexamethylpropyleneamine oxime (‎99mTc-HMPAO) SPECT is widely used for the evaluation of Alzheimer's ‎dementia (AD); we aim to assess superiority of one method over the ‎other. Methods: Twenty four patients with clinical diagnosi...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Coronary artery calcium (CAC) score – a prognostic tool in coronary artery disease?

Introduction: The aim of this study was to evaluate the impact of measurement of coronary artery calcification score (CAC) in patients with suspected coronary artery disease (CAD) and a normal myocardial perfusion scan. Methods: In a prospective study we measured the calcium score of 74 patients (29 m, 45 f, mean age 58.7 (m) and 64.4 (f)) with suspicion of CAD and a normal perfusion scan. In ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2011