Biomechanical Comparison of Osteoporotic Distal Radius Fractures Fixed by Distal Locking Screws with Different Length
نویسندگان
چکیده
OBJECTIVES To evaluate the postoperative stability of osteoporotic distal radius fractures fixed with distal locking screws with different length. METHODS A comminuted extra-articular dorsally unstable distal radius fracture, treated with volar locking plate system, was created. The 18 specimens were randomized into 3 groups based on distal locked screws with different length: Group A had unicortical screws with 50% length to the dorsal cortex. Group B had unicortical screws with 75% length to the dorsal cortex. Group C had bicortical screws. Axial compression and bending loads were imposed on the models before and after cycling testing as well as load to clinical and catastrophic failure. RESULTS Minimum change in stiffness was observed before and after fatigue for all groups. The final stiffness to bending forces was statistically similar in all groups, but stiffness to axial compression was statistically significant different: Group A approached significance with respect to groups B and C (P = 0.017, 0.009), whereas stiffness in group B and C was statistically similar (P = 0.93). Load to clinical failure was significantly less for group A (456.54±78.59 N) compared with groups B (580.24±73.85 N) and C (591.07±38.40 N). Load to catastrophic failure was statistically similar between groups, but mean values for Group A were 18% less than means for Group C. CONCLUSIONS The volar locking plate system fixed with unicortical locking screws with at least 75% length not only produced early stability for osteoporotic distal radius fractures, but also avoided extensor tendon complications due to dorsal screw protrusion.
منابع مشابه
A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملA locking contoured plate for distal fibular fractures: mechanical evaluation in an osteoporotic bone model using screws of different length.
Osteoporotic bone with poor mechanical capacity provides limited stability after fixation of ankle fractures. Stabilization with an implant providing increased fixation strength in osteoporotic bone could reduce failure rates of fixation and allow a more functional treatment. The purpose of this study was to evaluate a locking contoured plate for fixation of distal fibular fractures in comparis...
متن کاملUsing self-drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study
BACKGROUND Symptomatic extensor tendon irritation is a frequent complication in volar plate osteosynthesis of distal radius fractures. It is typically caused by dorsal screw protrusion and overdrilling of the dorsal cortex. The use of self-drilling locking screws (SDLS) could overcome both causes. The practical applicability of SDLS depends on two prerequisites: (1) the feasibility of preoperat...
متن کاملA biomechanical comparison of volar locked plating of intra-articular distal radius fractures: use of 4 versus 7 screws for distal fixation.
PURPOSE To determine whether the number of distal locking screws significantly affects stability of a cadaveric simulated distal radius fracture fixed with a volar locking plate. METHODS We created AO/ASIF type C2 fractures in 10 matched pairs of human fresh-frozen cadaveric wrists and then fixed them using volar locking plates. The number of distal locking screws used was 4 screws or 7 screw...
متن کاملThe influence of distal screw length on the primary stability of volar plate osteosynthesis—a biomechanical study
BACKGROUND Extensor tendon irritation is one of the most common complications following volar locking plate osteosynthesis (VLPO) for distal radius fractures. It is most likely caused by distal screws protruding the dorsal cortex. Shorter distal screws could avoid this, yet the influence of distal screw length on the primary stability in VLPO is unknown. The aim of this study was to compare 75 ...
متن کامل