Performance of HTLV-1 screening assays in Brazil.
نویسندگان
چکیده
In recent years a variety of studies have been carried out to compare the accuracy (generally expressed in terms of sensitivity and specificity) of commercially available anti-HTLV tests. None of these studies were performed in Brazil or in any other South American country. During the characterization of our Brazilian reference panel we evaluated the sensitivities and specificities of the Abbott HTLV EIA (100%; 89.7%) and the Biochrom HTLV-1/-2 ELISA (100%; 42.4%). Our conclusion was that both assays may be problematic in terms of correctly identifying HTLV-negative sera. We therefore adjusted the cut-off values using receiver operating characteristics (ROC). ROC analysis, which involves calculating sensitivity and specificity for several cut-off values, can be used to ascertain the co-variation in the specificity and sensitivity of any assay giving quantitative results. The optimum cut-off value for the assay in a given study population is the point that gives highest possible sensitivity in conjunction with a small false-positive fraction. Using the HTLV-1/-2 Western blot as the "gold standard", we were able to improve the specificity of the Biochrom HTLV-1/-2 assay to 95% without affecting its sensitivity of 100%. However, it seems that when using the Biochrom HTLV-1/-2 ELISA, there may be problems in separating positive and negative sera. In the case of the Abbott HTLV EIA, our ROC analysis revealed that the cut-off value suggested by the manufacturer was nearly identical to the optimum cut-off value. Adjustment will affect neither sensitivity nor specificity. However, a slight adjustment of the cut-off value result in a clearer separation of the positive and negative populations. Furthermore, we assume that this adjustment will help to avoid false-positive results when larger serum panels are investigated. Further investigations will show whether or not this problem is linked to the geographical regions where the test is performed (e.g. polyclonal stimulation due to parasitic infections in tropical countries).
منابع مشابه
Evaluation of Sensitivity and Specificity Performance of Elecsys HTLV-I/II Assay in a Multicenter Study in Europe and Japan
Screening of blood for human T-cell lymphotropic virus type 1 and type 2 (HTLV-1 and -2, respectively) is important to diagnose and prevent infection and ensure the safety of blood supplies. The Elecsys HTLV-I/II assay is a newly developed, electrochemiluminescence screening assay for the detection of HTLV-1/2 infection. The sensitivity and specificity of the Elecsys HTLV-I/II assay were determ...
متن کاملGeographic distribution of human T-lymphotropic virus types 1 and 2 among mothers of newborns tested during neonatal screening, Minas Gerais, Brazil.
OBJECTIVE To evaluate the geographic distribution of human T-lymphotropic virus types 1 and 2 (HTLV-1/2) in the State of Minas Gerais, Brazil, in puerperal women whose newborns were tested for HTLV-1/2 during neonatal screening, and to overlap seropositivity with social and economic status determinants. METHODS During September-November 2007, the dry-blood samples taken from newborns on filte...
متن کاملComparison of Western blotting and PCR assays for confirmation of HTLV-1 virus in volunteer blood donors
Abstract Background and Objectives Human T-cell lymphotropic virus type I (HTLV-I) has been associated with two diseases in humans such as adult T-cell leukemia/lymphoma (ATLL) and HTLV-associated myelopathy/tropical spastic Para paresis (HAM/TSP). About 5 to 10 million people are infected with HTLV-1 worldwide. In order to improve the blood safety and to prevent false positive results in bloo...
متن کاملPrevalence of Human T-lymphotropic virus type 1 and 2 among blood donors in Manaus, Amazonas State, Brazil
INTRODUCTION Human T-lymphotropic virus type 1 and 2 (HTLV-1/2) is endemic in Brazil, but few studies have investigated the seroprevalence of HTLV and its subtypes among blood donors in the capital city Manaus, Amazonas State, Brazil. AIM To estimate the seroprevalence of HTLV-1/2 and to identify circulating subtypes among blood donors in Manaus. MATERIALS AND METHODS Blood donors (2001-200...
متن کاملPerformances of HTLV serological tests in diagnosing HTLV infection in high-risk population of São Paulo, Brazil.
Testing problems in diagnosing human T-lymphotropic virus (HTLV) infection, mostly HTLV-II, have been documented in HIV/AIDS patients. Since December 1998, the Immunology Department of Instituto Adolfo Lutz (IAL) offers HTLV-I/II serology to Public Health Units that attend HTLV high-risk individuals. Two thousand, three hundred and twelve serum samples: 1,393 from AIDS Reference Centers (Group ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Zentralblatt fur Bakteriologie : international journal of medical microbiology
دوره 283 3 شماره
صفحات -
تاریخ انتشار 1996