Broadband Measurement of Coating Thermal Noise in Rigid Fabry–Pérot Cavities
نویسندگان
چکیده
We report on the relative length fluctuation of two fixed-spacer Fabry–Pérot cavities with mirrors fabricated from silica/tantala dielectric coatings on fused silica substrates. By locking a laser to each cavity and reading out the beat note ν̂ = ν1 − ν2 of the transmitted beams, we find that, for frequencies from 10 Hz to 1 kHz, the amplitude spectral density of beat note fluctuation is √ S ν̂( f ) = (0.5 Hz)/ f 1/2. By careful budgeting of noise sources contributing to the beat note, we find that our measurement is consistent with the fluctuation in this band being dominated by the Brownian noise of the mirror coatings. Fitting for the coating loss angle φc, we find it equal to 4×10−4. We then use a Bayesian analysis to combine our measurement with previous observations, and thereby extract estimates for the individual loss angles of silica and tantala. The testbed described in this article can be used in the future to measure the length noise of cavities formed with novel mirror coating materials and geometries.
منابع مشابه
An optical vernier technique for in situ measurement of the length of long Fabry–Pérot cavities
We propose a method for in situ measurement of the length of kilometre-sized Fabry–Pérot cavities in laser gravitational wave detectors. The method is based on the vernier, which occurs naturally when the laser beam incident on the cavity has a sideband. By changing the length of the cavity over several wavelengths we obtain a set of carrier resonances alternating with sideband resonances. From...
متن کاملContribution of Thermal Noise to Frequency Stability of Rigid Optical Cavity via Hertz-Linewidth Lasers
We perform detailed studies of state-of-the-art laser stabilization to high finesse optical cavities, revealing fundamental mechanical thermal noise-related length fluctuations. We compare the frequency noise of lasers tightly locked to the resonances of a variety of rigid Fabry-Perot cavities of differing lengths and mirror substrate materials. The results are in agreement with the theoretical...
متن کاملDirect Fabry-pérot Effect Removal
This study indicates that the removal of reflections from T-ray signals can be carried out in the frequency domain without prior knowledge of material parameters or sample thickness. By fitting polynomials to the logarithm and the argument of the sample’s transfer function, the Fabry-Pérot reflection term is canceled out, leading to disappearance of the reflections in spatial domain. The method...
متن کاملElectron polarization measurement using a Fabry-Pérot cavity at HERA
A new Compton longitudinal polarimeter currently under construction for HERA is presented. The key component of the polarimeter is a Fabry-Pérot cavity located around the electron beam pipe. With such an optical cavity, a continuous laser power equivalent to 5 kW, much higher than those commercially available, can be achieved, leading to one backscattered photon per bunch crossing. This “few-ph...
متن کاملSub-Hz line width diode lasers by stabilization to vibrationally and thermally compensated ULE Fabry- Perot cavities
We achieved a 0.5 Hz optical beat note line width with ~ 0.1 Hz/s frequency drift at 972 nm between two external cavity diode lasers independently stabilized to two vertically mounted Fabry-Perot (FP) reference cavities. Vertical FP reference cavities are suspended in mid-plane such that the influence of vertical vibrations to the mirror separation is significantly suppressed. This makes the se...
متن کامل