Are external knee load and EMG measures accurate indicators of internal knee contact forces during gait?

نویسندگان

  • Andrew J Meyer
  • Darryl D D'Lima
  • Thor F Besier
  • David G Lloyd
  • Clifford W Colwell
  • Benjamin J Fregly
چکیده

Mechanical loading is believed to be a critical factor in the development and treatment of knee osteoarthritis. However, the contact forces to which the knee articular surfaces are subjected during daily activities cannot be measured clinically. Thus, the ability to predict internal knee contact forces accurately using external measures (i.e., external knee loads and muscle electromyographic [EMG] signals) would be clinically valuable. We quantified how well external knee load and EMG measures predict internal knee contact forces during gait. A single subject with a force-measuring tibial prosthesis and post-operative valgus alignment performed four gait patterns (normal, medial thrust, walking pole, and trunk sway) to induce a wide range of external and internal knee joint loads. Linear regression analyses were performed to assess how much of the variability in internal contact forces was accounted for by variability in the external measures. Though the different gait patterns successfully induced significant changes in the external and internal quantities, changes in external measures were generally weak indicators of changes in total, medial, and lateral contact force. Our results suggest that when total contact force may be changing, caution should be exercised when inferring changes in knee contact forces based on observed changes in external knee load and EMG measures. Advances in musculoskeletal modeling methods may be needed for accurate estimation of in vivo knee contact forces.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between kinematic parameters of the lower limb and maximum ground reaction force during jumping and one-legged landing

Background: Anterior cruciate ligament injury is one of the most common injuries of the knee joint and prevention of this injury is of great importance(1). Considering that ground reaction forces are one of the load factors on the anterior cruciate ligament, Despite much research in this field to prevent ACL injury, the prevalence of this injury is still high(2). For example, previous studies h...

متن کامل

Variability of TKR Knee Kinematics and Relationship with Gait Kinetics: Implications for Total Knee Wear

Several factors, including compressive load and knee kinematics, have been shown to influence wear. External knee moments (a surrogate for load) have recently been correlated with the medial and lateral wear scar areas of an unconstrained, PCL retaining knee design. Therefore, the purpose of this study was to determine whether differences in kinetics during level walking are accompanied by spec...

متن کامل

The effect of internal and external foot rotation on the adduction moment and lateral-medial shear force at the knee during gait.

It has been hypothesised that those with medial compartment knee osteoarthritis tend to externally rotate their foot during gait in order to unload the diseased compartment. This has been found to decrease the adduction moment at the knee during late stance, although the effects of foot rotation on shear forces at the knee have not yet been determined. Also, the effects of internal foot rotatio...

متن کامل

The Effect of High Heel Shoes on Tibiofemoral and Patellofemoral joint Contact Forces and Muscle Forces

Introduction: High heel shoes affect the knee joint and can cause arthritis in the tibiofemoral (TFJ) and patellofemoral joints (PFJ). There is a dearth of research investigating the contact forces of TFJ and PFJ. Therefore, the purpose of this study was to assess the effect of high heel shoes on muscle forces as well as TFJ, and PFJ contact forces during walking.   Materials & Methods: A tot...

متن کامل

Direct comparison of measured and calculated total knee replacement force envelopes during walking in the presence of normal and abnormal gait patterns.

Knee joint forces measured from instrumented implants provide important information for testing the validity of computational models that predict knee joint forces. The purpose of this study was to validate a parametric numerical model for predicting knee joint contact forces against measurements from four subjects with instrumented TKRs during the stance phase of gait. Model sensitivity to abn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 31 6  شماره 

صفحات  -

تاریخ انتشار 2013