On-line measurement validation through confidence level based optimal estimation of a process variable

نویسندگان

  • Jari Näsi
  • Aki Sorsa
چکیده

In a continuous chemical process, the accuracy and reliability of process and analytical measurements creates the basis for control system performance and ultimately for product uniformity. Measurement results, whether from fast on-line measurement devices or from sample-based laboratory analyses, is the key for selecting the method for process control and analysis. Intelligent and advanced control methods, exploiting measurements, are of no benefit, if the measurements cannot be trusted. This report presents results from project where target was to develop validation and estimation method for combining real-time redundant signals, consisting of sensor data, and analytical measurements. The validation of on-line measurement uses less frequently updated but more accurate information to validate frequently updated but less accurate on-line measurements. Validation and estimation of measurements are the keys and prerequisites to efficient calibration of on-line measurement device. An estimate of the measured variable is obtained as a weighted average of the on-line measurements and laboratory analyses. The weighting coefficients are recursively updated in real time when new analyse and measurement results are available. The uncertainty of laboratory analysis must be below a specific limit, or the basic assumption of laboratory analyse being reliable and used as reference to on-line measurement device can not be used. The calibration and estimation filter has been tested by several data sets collected from an operating plant. The calculation of optimal estimate can be used in several industrial applications to produce additional information for more precise process control. In addition, pre-processed data can be used to calculate a “need for maintenance indicator” to warn the operator for sensor breakdowns, wearing or deterioration and detect calibration needs. The operator’s workload is thereby reduced especially in problematic situations where measurement and validation signals are not in convergent, by offering calculated best estimation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Confidence based estimation and deterioration indication of on-line measurement

In an industrial process, the accuracy and reliability of process creates basics for control system and ultimately to product uniformity. Measurement results, whether from fast on-line sensors or from samplebased laboratory analyses, is the key for selecting the method for process control and analysis. Intelligent and advanced control methods, exploiting measurements, are of no benefit if the m...

متن کامل

High-Performance Robust Three-Axis Finite-Time Attitude Control Approach Incorporating Quaternion Based Estimation Scheme to Overactuated Spacecraft

With a focus on investigations in the area of overactuated spacecraft, a new high-performance robust three-axis finite-time attitude control approach, which is organized in connection with the quaternion based estimation scheme is proposed in the present research with respect to state-of-the-art. The approach proposed here is realized based upon double closed loops to deal with the angular rate...

متن کامل

Determination of Residual Ceftazidime in Pharmaceutical Product line: A Cleaning Validation Study by HPLC

The manufacturing equipment in pharmaceutical industry, could be used in multiple and sharedproduction lines, therefore there is the possibility for the products components and active ingredients tointermix and pollute one another. In this purpose the cleaning methods are used, to reduce the residueslevels from the machinery surfaces and decrease the residues to acceptable level but these metho...

متن کامل

Process Improvement of Experimental Measurements Using D-optimal Models

In this paper, the application of D-optimal models, as an alternative to response surface models (RS models) for design of experiment (DOE) was examined. Two D-optimal models for tilt-rotors in the wind tunnel experiment, as a form of quadratic functions, were generated based on a chosen optimality criterion. This optimality criterion was used to generate the optimized sampled points in the des...

متن کامل

Multi-objective Measurement Devices Allocation Using State Estimation in Distribution System

Allocation of measurement devices is a necessity of distribution system which is an application of state estimation. In this paper, the problem of active and reactive measurement devices is modeling using a multi-objective method. The objectives of the problem are to minimize the use of measurement devices, increase in state estimation output, improve the state estimation quality and reduce cos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004