The effect of a tall tower on flow and dispersion through a model urban neighborhood: part 2. Pollutant dispersion.

نویسندگان

  • Laurie A Brixey
  • David K Heist
  • Jennifer Richmond-Bryant
  • George E Bowker
  • Steven G Perry
  • Russell W Wiener
چکیده

This article is the second in a two-paper series presenting results from wind tunnel and computational fluid dynamics (CFD) simulations of flow and dispersion in an idealized model urban neighborhood. Pollutant dispersion results are presented and discussed for a model neighborhood that was characterized by regular city blocks of three-story row houses with a single 12-story tower located at the downwind edge of one of these blocks. The tower had three significant effects on pollutant dispersion in the surrounding street canyons: drawing the plume laterally towards the tower, greatly enhancing the vertical dispersion of the plume in the wake of the tower, and significantly decreasing the residence time of pollutants in the wake of the tower. In the wind tunnel, tracer gas released in the avenue lee of the tower, but several blocks away laterally, was pulled towards the tower and lifted in the wake of the tower. The same lateral movement of the pollutant was seen in the next avenue, which was approximately 2.5 tower heights downwind of the tower. The tower also served to ventilate the street canyon directly in its wake more rapidly than the surrounding areas. This was evidenced by CFD simulations of concentration decay where the residence time of pollutants lee of the 12-story tower was found to be less than half the residence time behind a neighboring three-story building. This same phenomenon of rapid vertical dispersion lee of a tower among an array of smaller buildings was also demonstrated in a separate set of wind tunnel experiments using an array of cubical blocks. A similar decrease in the residence time was observed when the height of one block was increased.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of a tall tower on flow and dispersion through a model urban neighborhood: part 1. Flow characteristics.

Wind tunnel experiments were performed to examine the effect of a tall tower on the flow around an otherwise uniform array of buildings. Additionally, preliminary CFD simulations were run to visualize the flow with more resolution. The model used in both the wind tunnel and CFD studies was designed to simulate an area of Brooklyn, NY, USA, where blocks of residential row houses form a neighborh...

متن کامل

Modeling of carbon monoxide dispersion around the urban tunnel portals

The aim of this study is to investigate the problems caused by discharge of polluted air from tunnels into the environment with a specific focus on residential areas. In city tunnels, portal or stacks, pollutant management is a big challenge. Nowadays, air quality management, particularly in urban tunnels, is considered as a part of the ventilation system design. The goal is to see the environm...

متن کامل

Influence of avenue-trees on air quality at the urban neighborhood scale. Part I: quality assurance studies and turbulent Schmidt number analysis for RANS CFD simulations.

Flow and dispersion of traffic pollutants in a generic urban neighborhood with avenue-trees were investigated with Computational Fluid Dynamics (CFD). In Part I of this two-part contribution, quality assessment and assurance for CFD simulations in urban and vegetation configurations were addressed,before in Part II flow and dispersion in a generic urban neighborhood with multiple layouts of ave...

متن کامل

Study of Solute Dispersion with Source/Sink Impact in Semi-Infinite Porous Medium

Mathematical models for pollutant transport in semi-infinite aquifers are based on the advection-dispersion equation (ADE) and its variants. This study employs the ADE incorporating time-dependent dispersion and velocity and space-time dependent source and sink, expressed by one function. The dispersion theory allows mechanical dispersion to be directly proportional to seepage velocity. Initial...

متن کامل

Influence of avenue-trees on air quality at the urban neighborhood scale. Part II: traffic pollutant concentrations at pedestrian level.

Flow and dispersion of traffic-emitted pollutants were studied in a generic urban neighborhood for various avenue-tree layouts by employing 3D steady RANS simulations with the realizable k-ε turbulence model. In comparison to the tree-free situation quantitative and qualitative changes with flow reversal in the wind field were observed. Low to moderate increases (<13.2%) in the neighborhood-ave...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of environmental monitoring : JEM

دوره 11 12  شماره 

صفحات  -

تاریخ انتشار 2009