Isolation of Legionella pneumophilia from cooling tower water by filtration.
نویسندگان
چکیده
Methods are described for detection of Legionella pneumophila in cooling tower water or other water sources by direct fluorescent-antibody staining. A procedure for isolation of Legionella bacteria from water samples by guinea pig inoculation is described. Two different serogroups of L. pneumophila were isolated repeatedly from one of the cooling towers.
منابع مشابه
Isolation of Legionella pneumophila from Tehran Hospital Water Samples
Over a Period of three months (summer), 108 samples of water collected from four hospitals in Te-hran. They were taken from numerous potable and non-potable water, including main supply cis-terns, calorifiers, hot and cold tap water, shower, cooling tower and drain of air condition system. Culturing of concentrated and non-concentrated water samples on Buffered Charcoal Yeast Extract (BCYE) Aga...
متن کاملNegative enrichment procedure for isolation of Legionella pneumophila from seeded cooling tower water.
A negative enrichment procedure was developed which was capable of isolating Legionella pneumophila directly from seeded air-conditioning cooling tower water onto laboratory media. This procedure was based on an 8-h incubation under conditions that were bactericidal to the indigenous water microflora but merely bacteriostatic to L. pneumophila.
متن کاملIsolation of Legionella pneumophila from hospital cooling towers in Johor, Malaysia.
Water-based cooling towers and their water supply at two hospitals in Johor were surveyed for the presence Legionella pneumophila. L. pneumophila were grown from 19 (76%) out of 25 collected water samples. One hospital cooling tower was contaminated with L. pneumophila serogroup 1.
متن کاملIsolation of Legionella pneumophila from Tehran Hospital Water Samples
Over a Period of three months (summer), 108 samples of water collected from four hospitals in Tehran. They were taken from numerous potable and non-potable water, including main supply cisterns, calorifiers, hot and cold tap water, shower, cooling tower and drain of air condition system. Culturing of concentrated and non-concentrated water samples on Buffered Charcoal Yeast Extract (BCYE) Agar ...
متن کاملIsolation of Legionella Pneumophila Serogroups 1, 8 & 10 (Causative Agents of Legionnaires\' Disease) from Water Sources in Tehran, Iran
In this survey, 187 samples collected from 9 different sources of water in Tehran such as: water coolers, neonates incubators, water bathes (37° C), little pools in parks or squares, cooling towers, hot or cold water taps, were examined for Legionnaires' disease agents. Inoculating water samples on selective and nonselective media resulted in isolation of several strains of gram negative bact...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 41 5 شماره
صفحات -
تاریخ انتشار 1981