Scintigraphic method for evaluating reductions in local blood volumes in human extremities.
نویسندگان
چکیده
We introduce a new method for evaluating reductions in local blood volumes in extremities, based on the combined use of autologue injection of 99mTc-radiolabelled erythrocytes and clamping of the limb blood flow by the use of a tourniquet. Twenty-two healthy male volunteers participated in the experiment. Evaluation of one versus two scintigraphic projections, trials for assessment of the reproducibility, a comparison of the scintigraphic method with a water-plethysmographic method and registration of the fractional reduction in blood volume caused by exsanguination as a result of simple elevation were carried out. No significant differences between results obtained by the use of one or two scintigraphic projections were found. The between-subject coefficient of variation was 14% in the lower limb experiment and 11% in the upper limb experiment. The within-subject coefficient of variation was 6% in the lower limb experiment and 6% in the upper limb experiment. We found a significant relation (r = 0.42, p = 0.018) between the results obtained by the scintigraphic method and the plethysmographic method. In fractions, a mean reduction in blood volume of 0.49+0.14 (2 SD) was found after 1 min of elevation of the lower limb and a mean reduction of 0.45+/-0.10 (2 SD) after half a minute of elevation of the upper limb. We conclude that the method is precise and can be used in investigating physiologic and pathophysiologic mechanisms in relation to blood volumes of limbs not subject to research previously.
منابع مشابه
Studying Changes of the Effective Radius in Blood Vessels after Exposure of Lower Extremities to Periodical Mechanical Vibrations
Background: Previous studies demonstrated a health improving effect in patients underwent an automatic vibratory massage taking 10 minutes. One of reasons that may explain a healing effect of the automatic massage is a stimulated increase in both blood circulation through vascular system and effective size of blood vessels. Objective: This paper aims to quantify a contribution of the auto...
متن کاملA new scintigraphic method for determining left ventricular volumes.
A new scintigraphic count-based method for measuring absolute left ventricular volumes is presented. It is a fast and simple technique that allows geometrical assumptions to be avoided and is free of radiation attenuation corrections. This method requires the acquisition of an image of the left ventricle in the right anterior oblique projection and the collection of gated blood pool images in t...
متن کاملEvaluation of a new bombesin analogue labeled with 99mTc as potential targeted tumor scintigraphic agent
Background: Bombesin shows high affinity for Gastrin-releasing peptide (GRP) receptors which over expressed on the cell surfaces of several human tumors particularly in prostate and breast cancers. The aim of this study was labeling of designed analogue with99mTc via HYNIC and Tricine /EDDA and evaluation as potential targeted tumor scintigraphic agent. Materials and Methods: HYNIC-Bombesin wa...
متن کاملComparison of blood pressure measurements on the upper and lower extremities during spinal anesthesia
Introduction: During spinal anesthesia, measurement of blood pressure is often obtained by an indirect method using an inflatable cuff on the upper arm. The relationship between the blood pressure measurements at the two sites in patients undergoing spinal anesthesia is unclear. This study was designed to evaluate the difference observed in systolic blood pressure (SBP) taken from the upp...
متن کاملSerological, pathological and scintigraphic assessment of Hemiscorpius lepturus effects on renal dysfunction in rats
Objective(s): Hemiscorpius lepturus is one of the dangerous scorpions of Iran leading to acute kidney injury (AKI) especially in infants. The purpose of this animal study was to compare the serological, pathological and scintigraphic data to quickly predict the occurrence of this disorder.Materials and Methods: In two groups of animals, each contained five rats, H. lepturus venom (1200 µg/Kg) w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Scandinavian journal of clinical and laboratory investigation
دوره 60 5 شماره
صفحات -
تاریخ انتشار 2000