Screw length in volar locking plate fixation for distal radial fractures.

نویسندگان

  • Grace Yuen
  • Dennis K H Yee
  • Christian Fang
  • Tak-Wing Lau
  • Frankie Leung
چکیده

PURPOSE To develop a reference for the distal screw length in volar locking plate fixation for distal radial fractures in an East Asian population. METHODS 12 pairs of forearm specimens from 11 male and one female East Asian cadavers were scanned using computed tomography. On sagittal images of the distal radius, the mean cortex-to-cortex distance of 8 quadrants was measured as a reference for the distal screw length. In addition, intra-operative 3-dimensional fluoroscopy of 10 male and 10 female patients who underwent volar locking plate fixation for distal radial fractures was used to validate the distal screw length in the cadaveric reference. 76 distal locking screws were applied in the 8 quadrants; their cortex-to-cortex distances were measured. RESULTS The mean cortex-to-cortex distances at quadrants A, B, C, D, E, F, G, and H were 15.4 mm, 19.6 mm, 20.8 mm, 20.0 mm, 13.3 mm, 18.0 mm, 18.8 mm, and 17.4 mm, respectively. In 45% of the specimens, the 2 screws inserted at quadrants C and D were longest. Distal screws (quadrants A to D) were significantly longer than proximal screws (quadrants E to H) [p=0.02]. In intra-operative 3-dimensional fluoroscopic images, 2 of the 76 distal locking screws penetrated the dorsal cortex (one in quadrant A and one in quadrant F). The mean screw length was 88.0% of the cortex-to-cortex distance. Referenced to the cadaveric data, 88.2% of the screws could be safely inserted without penetrating the dorsal cortex, and the remaining 11.8% of screws (5 at quadrant D, one at quadrant B, and 3 at quadrant C; all in female patients) could potentially cause dorsal cortex penetration of 2 to 4 mm. In male patients, the mean screw length was 76.1% of the cortex-to-cortex distance based on the cadaveric reference. In female patients, when the screw length was 4 mm less than the cadaveric reference, the mean screw length would be 72.0% of the referenced cortex-to-cortex distance, with no dorsal cortex penetration. CONCLUSION In female patients, the screw length should be 4 mm less than the cadaveric reference to avoid dorsal cortex penetration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Comparison of volar locking plate and external fixation with K wire augmentation in unstable distal radius fractures

Distal radius fractures are one of the most common injuries and this incidence is likely to increase as the aging population increases. The type of operation and implant is a matter of discussion and randomized trials and meta analyses have failed to recommend the preferred implant. Internal fixation with volar locking plate and external fixation with supplementation with K wire have been succe...

متن کامل

Polyaxial versus uniaxial volar locking plate for distal radial fractures.

PURPOSE To compare the penetration of the distal screws in relation to the thickness of the distal metaphysis in the polyaxial versus uniaxial volar locking plates. METHODS Records of 78 patients aged 16 to 79 years who underwent open reduction and internal fixation for distal radial fractures (n=81) were reviewed. All fracture subtypes were included. 20 men and 22 women aged 18 to 79 (mean, ...

متن کامل

Mechanical failure of the distal radius volar locking plate.

PURPOSE To review 9 cases of mechanical failure of the volar locking plate for distal radial fractures. METHODS Records of 374 consecutive patients who underwent volar locking plating for distal radial fractures were reviewed. Mechanical failures of the volar locking plate were defined as plate breakage or bending, screw breakage or loosening, or collapse of articular fragments resulting in i...

متن کامل

Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model

BACKGROUND The locking screws target the radial styloid, theoretically provide greater stability against radial styloid fragment. However, it is unknown whether the radial styloid locking screws increased the stability of the volar plating system fixation along the entire distal radius or not. In this study, we evaluated the stability of the volar plating system fixation with or without the rad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 23 2  شماره 

صفحات  -

تاریخ انتشار 2015