Technique for cranial CT scanning of excessively obese patients.

نویسندگان

  • I J Finch
  • Y Sun
  • S A Shatsky
چکیده

Received June 28, 1988; accepted August 14, 1988. metal suspension device, can be lifted or lowered by means of a hand crank that controls the elevation of the frame. In the CT suite, the patient is placed supine on a plastic spinal buckboardl A single sling is positioned underneath the buckboard at the level of the patient's thighs. The sling is then connected to two Hoyer lifts, one on each side of the CT table (Fig. 1 ). The legs of the lifts are anchored with approximately 40 lb. (18 kg) of weight to stabilize them. The lifts are then cranked up approximately 3 em to reduce the patient's weight on the table. We have found that by positioning the sling at thigh level, the patient and sling will move freely with the table, permitting accurate scanning at 1 0-mm slice intervals. The Hoyer lifts themselves remain stationary. Using this method we performed three studies on two patients , one 350 lb. (159 kg) and the other 329 lb. (149 kg). We obtained a scout image and approximately 12 1 0-mm contiguous axial slices. The time required for each procedure was similar to that for a standard cranial CT. All scans were performed on a GE 9800 unit.~ which has a weight limit of 320 lb. (145 kg) for head scanning. All studies were of high quality and eminently diagnostic.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of radiation dose to the lens of eyes of patients undergoing cranial computed tomography in a teaching Hospital in Osun state, Nigeria

Background: One of the means of assessing dose to patients from Computed tomography (CT) procedure is through the determination of the skin entrance dose (ESD) with the appreciation of the concern that ocular exposure effects from CT scan includes possible induction of cancer and cataract. Due to the relatively more recent introduction of CT scans, little work has been done in this area in the ...

متن کامل

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...

متن کامل

Technique for plain CT and CT angiogram of the head in an obese patient.

BACKGROUND The increase in obesity in the general population brings more frequent challenges in imaging, as an increasing number of patients exceed the weight or girth limits of existing computed tomogram (CT) or magnetic resonance (MR) scanners. We describe a technique used for plain CT and CT angiogram of the head in a morbidly obese patient. CASE REPORT A 46-year-old man presented to the eme...

متن کامل

18F-FDG PET/CT in Neurolymphomatosis: Report of 3 Cases

Neurolymphomatosis is a rare manifestation of non-Hodgkin lymphoma characterized by infiltration of peripheral nerves, nerve roots, plexus and cranial nerves by malignant lymphocytes. This report presents positron emission tomography/computed tomography (PET/CT)imaging with 2-deoxy-2-18F-fluoro-D-glucose (18F-FDG) in 3 cases of non-Hodgkin lymphoma with nerve infiltration, including one newly d...

متن کامل

The comparison of serial SPECT-CT imaging to estimate absorbed dose to the organ at risk from peptide receptor radionuclide therapy dosimetry

Introduction: In Peptide Receptor Radionuclide Therapy (PRRT), the administration of radionuclide such as Lu-177 label with a pharmaceutical agent useful to destroy the lesion. The amount of Lu-177 radioactivity administered to the patients is still not standardize and generally not more than 7.4 GBq per session due to the patient’s safety issues. The first cycle of Lu-177 is a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 10 2  شماره 

صفحات  -

تاریخ انتشار 1989