Cup position alone does not predict risk of dislocation after hip arthroplasty.
نویسندگان
چکیده
We used a large prospective institutional registry to determine if there is a 'safe zone' that exists for acetabular component position within which the risk of hip dislocation is low and if other patient and implant factors affect the risk of hip dislocation. Patients who reported a dislocation event within six months after hip arthroplasty surgery were identified, and acetabular component position was measured with anteroposterior radiographs. The frequency of dislocation was 2.1% (147 of 7040 patients). No significant difference was found in the number of dislocated hips among the radiographic zones (±5°,±10°,±15° boundaries). Dislocators <50 years old were less active preoperatively than nondislocators (P=0.006). Acetabular component position alone is not protective against instability.
منابع مشابه
Risk factors for early dislocation after total hip arthroplasty: a matched case-control study.
PURPOSE To evaluate risk factors for early dislocation after primary total hip arthroplasty (THA). METHODS Records of 175 cases with dislocation during hospitalisation after THA and 651 controls without dislocation were reviewed. Cases and controls were matched for age, gender, body mass index classification, primary diagnosis, cup design, hospital, and year of intervention. Version and incli...
متن کاملAcetabular cup position and risk of dislocation in primary total hip arthroplasty
Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones f...
متن کاملEffects of Spinopelvic Balance on Acetabular Version in Total Hip Arthroplasty
The orientation of acetabular component is influenced by pelvic tilt, body position and individual variation in pelvic parameters. Most adverse events attribute to improper positioning of the acetabular component in the functional position. There is evidence that the orientation of the pelvis changes from the supine to standing position, consequently changing the orientation of acetabular cup v...
متن کاملCup positioning in total hip arthroplasty.
The "optimal" positioning of the cup in total hip arthroplasty can improve hip function and reduce wear, impingement and dislocation. The cup position is described as the spatial relation between the hip rotation centre and the pelvis and, as the cup orientation around the rotation centre. The first parameter affects hip balance and, if not managed properly, might result in poor function and le...
متن کاملRedefining the Acetabular Component Safe Zone for Posterior Approach Total Hip Arthroplasty.
BACKGROUND Acetabular component orientation influences joint stability in total hip arthroplasty (THA). The purpose of this study was to evaluate the effect of cup orientation and other variables on hip dislocation risk and to define a posterior approach specific safe zone. METHODS A cohort of 1289 posterior approach primary THA cases was prospectively followed and component position measured...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 30 1 شماره
صفحات -
تاریخ انتشار 2015