Actigraphy-based sleep estimation in adolescents and adults: a comparison with polysomnography using two scoring algorithms

نویسندگان

  • Mirja Quante
  • Emily R Kaplan
  • Michael Cailler
  • Michael Rueschman
  • Rui Wang
  • Jia Weng
  • Elsie M Taveras
  • Susan Redline
چکیده

Objectives Actigraphy is widely used to estimate sleep-wake time, despite limited information regarding the comparability of different devices and algorithms. We compared estimates of sleep-wake times determined by two wrist actigraphs (GT3X+ versus Actiwatch Spectrum [AWS]) to in-home polysomnography (PSG), using two algorithms (Sadeh and Cole-Kripke) for the GT3X+ recordings. Subjects and methods Participants included a sample of 35 healthy volunteers (13 school children and 22 adults, 46% male) from Boston, MA, USA. Twenty-two adults wore the GT3X+ and AWS simultaneously for at least five consecutive days and nights. In addition, actigraphy and PSG were concurrently measured in 12 of these adults and another 13 children over a single night. We used intraclass correlation coefficients (ICCs), epoch-by-epoch comparisons, paired t-tests, and Bland-Altman plots to determine the level of agreement between actigraphy and PSG, and differences between devices and algorithms. Results Each actigraph showed comparable accuracy (0.81-0.86) for sleep-wake estimation compared to PSG. When analyzing data from the GT3X+, the Cole-Kripke algorithm was more sensitive (0.88-0.96) to detect sleep, but less specific (0.35-0.64) to detect wake than the Sadeh algorithm (sensitivity: 0.82-0.91, specificity: 0.47-0.68). Total sleep time measured using the GT3X+ with both algorithms was similar to that obtained by PSG (ICC=0.64-0.88). In contrast, agreement between the GT3X+ and PSG wake after sleep onset was poor (ICC=0.00-0.10). In adults, the GT3X+ using the Cole-Kripke algorithm provided data comparable to the AWS (mean bias=3.7±19.7 minutes for total sleep time and 8.0±14.2 minutes for wake after sleep onset). Conclusion The two actigraphs provided comparable and accurate data compared to PSG, although both poorly identified wake episodes (i.e., had low specificity). Use of actigraphy scoring algorithm influenced the mean bias and level of agreement in sleep-wake times estimates. The GT3X+, when analyzed by the Cole-Kripke, but not the Sadeh algorithm, provided comparable data to the AWS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Activity-based sleep-wake identification: an empirical test of methodological issues.

The effects of actigraph placement and device sensitivity on actigraphic automatic sleep-wake scoring were assessed using concomitant polysomnographic and wrist actigraphic data from dominant and nondominant hands of 20 adults and 16 adolescents during 1 laboratory night. Although activity levels differed between dominant and nondominant wrists during periods of sleep (F = 4.57; p < 0.05) and w...

متن کامل

Validation of midsagittal jaw movements to measure sleep in healthy adults by comparison with actigraphy and polysomnography

OBJECTIVE In a device based on midsagittal jaw movements analysis, we assessed a sleep-wake automatic detector as an objective method to measure sleep in healthy adults by comparison with wrist actigraphy against polysomnography (PSG). METHODS Simultaneous and synchronized in-lab PSG, wrist actigraphy and jaw movements were carried out in 38 healthy participants. Epoch by epoch analysis was r...

متن کامل

ACTIGRAPHY FOR ADOLESCENT SLEEP INTRODUCTION ADOLESCENCE IS A TIME OF RAPID CHANGES IN SLEEP PATTERNS AND OF RISING PREVALENCE OF SLEEPI- NESS, WITH ADOLESCENTS HAVING BEEN IDENTIFIED as being at high risk for problem sleepiness.1 Sleep deprivation

ADOLESCENCE IS A TIME OF RAPID CHANGES IN SLEEP PATTERNS AND OF RISING PREVALENCE OF SLEEPINESS, WITH ADOLESCENTS HAVING BEEN IDENTIFIED as being at high risk for problem sleepiness.1 Sleep deprivation among adolescents is a rising concern among parents, health professionals, and educators.2,3,4,5,6 In light of the concerns and growing awareness of the problems associated with adolescent sleep,...

متن کامل

Wake detection capacity of actigraphy during sleep.

STUDY OBJECTIVES To evaluate the ability of actigraphy compared to polysomnography (PSG) to detect wakefulness in subjects submitted to 3 sleep conditions with different amounts of wakefulness: a nocturnal sleep episode and 2 daytime recovery sleep episodes, one with placebo and one with caffeine. A second objective was to compare the ability of 4 different scoring algorithms (2 threshold algor...

متن کامل

Evaluating sleep in bipolar disorder: comparison between actigraphy, polysomnography, and sleep diary.

OBJECTIVES Bipolar disorder is an illness characterized by sleep and circadian disturbance, and monitoring sleep in this population may signal an impending mood change. Actigraphy is an important clinical and research tool for examining sleep, but has not yet been systematically compared to polysomnography or sleep diary in bipolar disorder. The present study compares actigraphy, polysomnograph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2018