Effect of albuterol on expiratory resistance in mechanically ventilated patients.

نویسندگان

  • Eumorfia Kondili
  • Christina Alexopoulou
  • George Prinianakis
  • Nektaria Xirouchaki
  • Katerina Vaporidi
  • Dimitris Georgopoulos
چکیده

BACKGROUND In mechanically ventilated patients with COPD, the response of the expiratory resistance of the respiratory system (expiratory R(RS)) to bronchodilators is virtually unknown. OBJECTIVE To examine the effect of inhaled albuterol on expiratory R(RS), and the correlation of albuterol-induced changes in expiratory R(RS) with end-inspiratory resistance and the expiratory flow-volume relationship. METHODS We studied 10 mechanically ventilated patients with COPD exacerbation, before and 30 min after administration of albuterol. We obtained flow-volume curves during passive expiration, divided the expired volume into 5 equal volume slices, and then calculated the time constant and dynamic effective deflation compliance of the respiratory system (effective deflation C(RS)) of each slice via regression analysis of the volume-flow and post-occlusion volume-tracheal pressure relationships, respectively. For each slice we calculated expiratory R(RS) as the time constant divided by the effective deflation C(RS). RESULTS Albuterol significantly decreased the expiratory R(RS) (mean expiratory R(RS) 42.68 ± 17.8 cm H(2)O/L/s vs 38.08 ± 16.1 cm H(2)O/L/s) and increased the rate of lung emptying toward the end of expiration (mean time constant 2.51 ± 1.2 s vs 2.21 ± 1.2 s). No correlation was found between the albuterol-induced changes in expiratory R(RS) and that of end-inspiratory resistance. Only at the end of expiration did albuterol-induced changes in the expiratory flow-volume relationship correlate with changes in expiratory R(RS) in all patients. CONCLUSIONS In patients with COPD, albuterol significantly decreases expiratory resistance at the end of expiration. In mechanically ventilated patients, neither inspiratory resistance nor the whole expiratory flow-volume curve may be used to evaluate the bronchodilator response of expiratory resistance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bronchodilator therapy with metered-dose inhaler and spacer versus nebulizer in mechanically ventilated patients: comparison of magnitude and duration of response.

OBJECTIVE Four-hour comparison of the bronchodilator response of albuterol administered via metered-dose inhaler (MDI) with spacer versus small-volume nebulizer (SVN) to mechanically ventilated patients with chronic obstructive pulmonary disease (COPD). DESIGN Prospective randomized clinical trial. SETTING Medical intensive care unit in a university hospital. PATIENTS Thirteen mechanicall...

متن کامل

Effect of Oral Drop Gastrolit (Zataria multiflora) on Gastric Residual Volume in Mechanically Ventilated Patients Hospitalized in the Intensive Care Units

Background: Proper nutritional support is one of the important caring aspects in patients who were hospitalized in ICU. Objective: This study was done to investigate Oral Drop Gastrolit effect on the gastric residual volume (GRV) in mechanically ventilated patients hospitalized in ICU. Methods: In this clinical trial, 50 mechanically ventilated patients were recruited using convenience sampli...

متن کامل

تأثیر فشردن قفسه سینه در زمان بازدم قبل از ساکشن داخل تراشه بر تبادل گازهای خون شریانی بیماران تحت تهویه مکانیکی

  Background & Aim : Endotracheal suctioning is one of the most frequently used methods for airway clearance in patients under mechanical ventilation. Chest physiotherapy techniques such as expiratory rib cage compression before endotracheal suctioning can be used as a means to facilitate mobilizing and removing airway secretions and improving alveolar ventilation. This study was carried out to...

متن کامل

Evaluation of the Effect of Nebulized N-Acetylcysteine on Respiratory Secretions in Mechanically Ventilated Patients: Randomized Clinical Trial

Background: The purpose of our study was to evaluate an inexpensive and available method to reduce mucous impactions in mechanically ventilated patients.Methods: This randomized clinical trial was conducted on 40 mechanically ventilated patients aged 15-90 years. The patients were randomly allocated into two arms; 20 cases and 20 controls. The cases received N-acetylcysteine via their nebulizer...

متن کامل

Effect of Acupressure on Gastric Content Aspiration in Mechanically Ventilated Patients Hospitalized in Intensive Care Units

Background and Objectives: Aspiration is a serious complication that occurs due to delayed gastric emptying in mechanically ventilated patients. Aspiration results in increased rate of pneumonia and death. Acupressure can increase gastric motility and prevent aspiration. This study aimed to determine the effect of acupressure on occurrence of gastric content aspiration in mechanically ventilate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 56 5  شماره 

صفحات  -

تاریخ انتشار 2011