Long-term efficacy of a mini-course in radiation-reducing techniques in invasive cardiology.

نویسندگان

  • E Kuon
  • K Empen
  • K Weitmann
  • A Staudt
  • A Hummel
  • M Dörr
  • T Reffelmann
  • W Hoffmann
  • S B Felix
چکیده

PURPOSE To validate the long-term efficacy of a 90-min. educational mini-course in less-irradiating cardiac interventional techniques. MATERIALS AND METHODS Before, two months after, and two years after the mini-course (periods I, II, and III), we analyzed the following radiation dose parameters for ten coronary angiographies (CA), performed by each of 7 cardiologists: total dose-area product (DAP), radiographic and fluoroscopic DAP fractions, number of radiographic frames and runs, and fluoroscopy time. RESULTS The median patient DAP for periods I, II and III was 31.4, 15.8 and 8.5 Gy × cm2, respectively. The long-term effect was related to shorter median fluoroscopy times (180, 172, and 120 s), shorter (57, 52, and 45) and fewer (12, 12, and 10) radiographic runs, consistent collimation and restriction to an adequate image quality. Both radiographic DAP/frame (28.7, 17.0, and 18.4 mGy × cm2) and fluoroscopic DAP/second (45.7, 24.2, and 10.0 mGy × cm2) decreased significantly. The multivariate linear regression analysis confirmed the increasing efficacy of the mini-course itself (-44.6 and -60.7%), and revealed a decreasing influence of the interventionalist's experience (-8.6% and -4.9% per 1,000 CAs, lifelong performed until the mini-course). The number of CAs performed after the mini-course did not influence the long-term DAP results. CONCLUSION The presented educational mini-course allows a significant, long-lasting, and apparently ongoing reduction of patient radiation exposure due to CA. A self-surveillant documentation of relevant radiation parameters is well suited to monitor and improve each operator's individual long-term radiation-reducing efforts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concise, intensive or longitudinal medical education courses, which is more effective in perceived self-efficacy and development of faculty members?

  Background: Teachers’ self-efficacy and development may be conceptualized as their beliefs in their own ability to plan, organize and carry out activities that are required to attain educational goals. In this study, we examined the effect of different medical education training courses (six-day, one- month short- term and six-month long- term courses) on perceived self-effica...

متن کامل

Efficacy of a minicourse in radiation-reducing techniques in invasive cardiology: a multicenter field study.

OBJECTIVES Our goal was to validate an educational 90-min minicourse in lower-irradiating cardiac invasive techniques. BACKGROUND Despite comprehensive radiation safety programs, patient radiation exposure in invasive cardiology remains considerable. METHODS Before and at a median period of 3.7 months after the minicourse at 32 German cardiac centers, 177 interventionalists consistently doc...

متن کامل

Efficacy of Fluconazole Prophylaxis on Invasive Candidiasis Infection in Extremely Low Birth Weight Neonates

Background: Invasive candidiasis infection is one of the main life-threatening problems for extremely low birth weight (ELBW) neonates who are in the neonatal intensive care unit (NICU). Candidiasis can cause mortality, short-term morbidity, and long-term neurodevelopmental outcome in infected infants who survive. Therefore, since several years ago fluconazole prophylaxis has begun for prematur...

متن کامل

مقایسه اثر مداخلات حمایتی روانی- اجتماعی بر نشانه های اختلال استرس پس از سانحه بازماندگان زلزله بم

Background: Many studies have shown the efficacy of cognitive – behavioral therapy and psychological debriefing in treatment of post traumatic stress disorder (PTSD) and a few evidences are available for using these techniques in large scale disasters. This study aimed to asses the effect of some psychological interventions in reducing PTSD symptoms after Bam earthquake in different age gr...

متن کامل

Low-power density of 950 MHz radiation does not affect long-term potentiation in rat dentate gyrus

Introduction: Over the last decade, exposure to non-ionizing electromagnetic waves due to base station antenna has increased. This in vivo study was planned for evaluating the effects of whole-body exposure to 950 MHz field of GSM mobile phone system on rat dentate gyrus long-term potentiation. Materials and Methods: 24 naive male Wistar rats (3 month old, 225|¡|25 g) were randomly divided in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin

دوره 185 8  شماره 

صفحات  -

تاریخ انتشار 2013