Patellar clunk syndrome in fixed-bearing posterior-stabilised versus cruciate-substituting prostheses.

نویسندگان

  • Yan Ho Tang
  • Wing Keung Wong
  • Hok Leung Wong
چکیده

PURPOSE To compare the outcome of fixed-bearing posterior-stabilised versus cruciate-substituting prostheses in 46 patients who underwent primary bilateral total knee replacement (TKR). METHODS Records of 35 women and 11 men aged 54 to 78 (mean, 67) years who underwent primary bilateral TKR for osteoarthritis (n=44) and rheumatoid arthritis (n=2) were retrospectively reviewed. A fixed-bearing posterior-stabilised prosthesis (Zimmer NexGen Legacy flex [LPS-Flex]) was used in one knee, and a fixed-bearing cruciate-substituting prosthesis (Depuy Press Fit Condylar Sigma CS [PFC CS]) was used in the contralateral knee. The mean time interval between the 2 operations was 34 (range, 4-60) months. All operations were performed by the same group of surgeons using standardised techniques. The medial parapatellar approach was used, and the patella was resurfaced. Rehabilitation was also standardised. Outcome measures included the pre- and post-operative active range of movement and the American Knee Society Score. Postoperative complications were documented. RESULTS At one year, the mean fixed flexion contracture, maximum flexion, and American Knee Society scores in knees with PFC CS and LPS-Flex prostheses were comparable. Three knees with the PFC CS prosthesis developed the patellar clunk syndrome, compared to none with the LPS-Flex prosthesis (p=0.24). The onset of the patellar clunk syndrome was around one year after surgery. Despite this, the axial alignment and rotation of the femoral and tibial components were good. CONCLUSION Both prostheses produce good clinical outcome. The PFC CS prosthesis is more likely to be associated with the patellar clunk syndrome.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The incidence of the patellar clunk syndrome in a recently designed mobile-bearing posteriorly stabilised total knee replacement.

The patellar clunk syndrome describes painful catching, grinding or jumping of the patella when the knee moves from a flexed to an extended position after total knee replacement (TKR). The posterior stabilised TKR had been noted to have a higher incidence of this problem. Mobile-bearing posteriorly stabilised TKRs have been introduced to improve patellar tracking and related problems by a mecha...

متن کامل

Mobile- versus fixed-bearing modern total knee replacements – which is the more patella-friendly design?

OBJECTIVES Our study aimed to examine if a mobile-bearing total knee replacement (TKR) offered an advantage over fixed-bearing designs with respect to rates of secondary resurfacing of the patella in knees in which it was initially left unresurfaced. METHODS We examined the 11-year report of the New Zealand Joint Registry and identified all primary TKR designs that had been implanted in > 500...

متن کامل

Early results of posterior-stabilised NexGen Legacy total knee arthroplasty.

OBJECTIVE To retrospectively assess the early results of the NexGen Legacy posterior-stabilised total knee prosthesis, which is a newer version of the Insall-Burstein II posterior-stabilised implant. METHODS 48 consecutive elderly patients had 60 NexGen Legacy posterior-stabilised total knees. The mean follow-up duration was 21 months. Clinical evaluation was performed according to the Knee S...

متن کامل

A kinematic comparison of fixed- and mobile-bearing knee replacements.

Mobile-bearing posterior-stabilised knee replacements have been developed as an alternative to the standard fixed- and mobile-bearing designs. However, little is known about the in vivo kinematics of this new group of implants. We investigated 31 patients who had undergone a total knee replacement with a similar prosthetic design but with three different options: fixed-bearing posterior cruciat...

متن کامل

In vitro measurement of patellofemoral force after three types of knee replacement.

Using a new, non-invasive method, we measured the patellofemoral force (PFF) in cadaver knees mounted in a rig to simulate weight-bearing. The PFF was measured from 20 degrees to 120 degrees of flexion before and after implanting three designs of knee prosthesis. Medial unicompartmental arthroplasty with a meniscal-bearing prosthesis and with retention of both cruciate ligaments caused no signi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2014