Contrast Media in Abdominal Computed Tomography: Optimization of Delivery Methods
نویسندگان
چکیده
OBJECTIVE To provide a systematic overview of the effects of various parameters on contrast enhancement within the same population, an animal experiment as well as a computer-aided simulation study was performed. MATERIALS AND METHODS In an animal experiment, single-level dynamic CT through the liver was performed at 5-second intervals just after the injection of contrast medium for 3 minutes. Combinations of three different amounts (1, 2, 3 mL/kg), concentrations (150, 200, 300 mgI/mL), and injection rates (0.5, 1, 2 mL/sec) were used. The CT number of the aorta (A), portal vein (P) and liver (L) was measured in each image, and time-attenuation curves for A, P and L were thus obtained. The degree of maximum enhancement (Imax) and time to reach peak enhancement (Tmax) of A, P and L were determined, and times to equilibrium (Teq) were analyzed. In the computed-aided simulation model, a program based on the amount, flow, and diffusion coefficient of body fluid in various compartments of the human body was designed. The input variables were the concentrations, volumes and injection rates of the contrast media used. The program generated the time-attenuation curves of A, P and L, as well as liver-to-hepatocellular carcinoma (HCC) contrast curves. On each curve, we calculated and plotted the optimal temporal window (time period above the lower threshold, which in this experiment was 10 Hounsfield units), the total area under the curve above the lower threshold, and the area within the optimal range. RESULTS A. Animal Experiment: At a given concentration and injection rate, an increased volume of contrast medium led to increases in Imax A, P and L. In addition, Tmax A, P, L and Teq were prolonged in parallel with increases in injection time The time-attenuation curve shifted upward and to the right. For a given volume and injection rate, an increased concentration of contrast medium increased the degree of aortic, portal and hepatic enhancement, though Tmax A, P and L remained the same. The time-attenuation curve shifted upward. For a given volume and concentration of contrast medium, changes in the injection rate had a prominent effect on aortic enhancement, and that of the portal vein and hepatic parenchyma also showed some increase, though the effect was less prominent. A increased in the rate of contrast injection led to shifting of the time enhancement curve to the left and upward. B. Computer Simulation: At a faster injection rate, there was minimal change in the degree of hepatic attenuation, though the duration of the optimal temporal window decreased. The area between 10 and 30 HU was greatest when contrast media was delivered at a rate of 2-3 mL/sec. Although the total area under the curve increased in proportion to the injection rate, most of this increase was above the upper threshold and thus the temporal window was narrow and the optimal area decreased. CONCLUSION Increases in volume, concentration and injection rate all resulted in improved arterial enhancement. If cost was disregarded, increasing the injection volume was the most reliable way of obtaining good quality enhancement. The optimal way of delivering a given amount of contrast medium can be calculated using a computer-based mathematical model.
منابع مشابه
Induction of DNA damage, apoptosis and micronuclei in peripheral blood lymphocytes following injection of contrast media in patients with abdominal CT scan
Background: Medical diagnostic procedures such as X-ray and computed Tomography (CT) scan account for considerable percent of patient's exposure to ionizing radiation. The exposure of cells to Ionization radiation results in induction of DNA damage and chromosomal aberrations. Contrast media (CM) are widely used in diagnostic radiology and CT scan. The aim of this study was to study adverse gen...
متن کاملAssessment of Contrast Media Volume Injected and Image Contrast in Abdominal Pelvic CT Scan and Related Factors in Referral Hospitals in Mazandaran, Iran
Background and purpose: Computed tomography scan (CT) is highly capable of diagnosing abdominal and pelvic lesions. Injection of contrast media at appropriate concentration and volume provides the least side effects and the highest image quality. This study aimed at investigating the volume of contrast medium injected and the level of image contrast compared to the standard model, in the imagi...
متن کاملMonte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کاملComparison between Needle Biopsy under Guide of Conventional Computerized Tomography (CCT) and Fluoroscopic Computerized Tomography (FCT) in Abdominal, Mediastinal, Lung, Pelvic, Bone, and Liver Masses
Background and Objective: Computerized tomography and fluoroscopic computerized tomography are amongst the methods used for guiding needle biopsy processes; however, fluoroscopic computerized tomography demonstrates the images during the process of biopsy. This study aims to compare and contrast the success of biopsy under guide...
متن کاملComputed tomographic anatomy of the abdominal region of cat
The purpose of this study was to identify the anatomic structures of the abdominal region of cat throughcomputed tomography (CT) to be used by veterinary radiologists, clinicians and surgeons. The abdominalregion of four cats were scanned twice, with and without using contrast medium in a same position, usinghigh-resolution imaging protocol. Slice intervals were 11 mm and were adjusted so that ...
متن کاملDiagnostic Reference Level of Computed Tomography Examinations and Need for Dose Optimization in Ondo State, Nigeria
Introduction: The present study was conducted to obtain State diagnostic reference levels (DRLs) of five routine computed tomography (CT) examinations from two CT centers in Ondo State and to identify factors responsible for dose variation and escalation in these CT centers. Material and Methods: Acquisition parameters and CT dose indices wer...
متن کامل