Upper limit of vulnerability reliably predicts the defibrillation threshold in humans.

نویسندگان

  • C Hwang
  • C D Swerdlow
  • R M Kass
  • E S Gang
  • W J Mandel
  • C T Peter
  • P S Chen
چکیده

BACKGROUND The upper limit of vulnerability is the stimulus strength above which electrical stimulation cannot induce ventricular fibrillation even when the stimulus occurs during the vulnerable period of the cardiac cycle. The purpose of this study was to test the hypothesis that the upper limit of vulnerability can accurately predict the defibrillation threshold in patients undergoing implantable cardioverter-defibrillator (ICD) implantation using nonthoracotomy lead systems. METHODS AND RESULTS We studied 77 patients at the time of ICD implantation. Multiple endocardial-endocardial and endocardial-subcutaneous shock pathways were used. Two different protocols were used to test the upper limit of vulnerability. In protocol 1 (n = 17), the upper limit of vulnerability was tested with two shocks on the peak or the up-slope of the T wave of paced rhythm. The shocks were given randomly either at the peak and 20 milliseconds before the peak of T wave (n = 7) or at 20 and 40 milliseconds before the peak of T wave (n = 10). In protocol 2 (n = 60), the upper limit of vulnerability was tested with three shocks delivered at 0, 20, and 40 milliseconds before the peak of the T wave. The weakest shock that failed to induce ventricular fibrillation by a 5-J step-down or step-up method was defined as the upper limit of vulnerability. The defibrillation threshold was also determined by a 5-J step-down or step-up method. In protocol 1, the upper limit of vulnerability (9 +/- 6 J) was significantly lower than the defibrillation threshold (13 +/- 7 J) with a correlation coefficient of .87 and P < .001. In protocol 2, the upper limit of vulnerability (13 +/- 6 J) was not significantly different from the defibrillation threshold (13 +/- 6 J) with a correlation coefficient of .85 and P < .001. In 45 of the 60 patients, the upper limit of vulnerability was < or = 15 J; all had a defibrillation threshold of < or = 20 J. In 51 of the 60 patients, the upper limit of vulnerability was within 5 J of the defibrillation threshold. The upper limit of vulnerability overestimated the defibrillation threshold by > 10 J in 8 patients and underestimated the defibrillation threshold by > 10 J in only 1 patient. The overestimation and underestimation occurred only in patients with the upper limit of vulnerability > 15 J. CONCLUSIONS When tested with three shocks on and before the peak of the T wave, the upper limit of vulnerability accurately predicted the defibrillation threshold in patients undergoing ICD implantation using nonthoracotomy lead systems. This method required either one or no episodes of ventricular fibrillation in most patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Upper Limit of Vulnerabilit Reliably Predicts the Defibrillation Threshold in Humans

Background The upper limit of vulnerability is the stimulus strength above which electrical stimulation cannot induce ventricular fibrillation even when the stimulus occurs during the vulnerable period of the cardiac cycle. The purpose of this study was to test the hypothesis that the upper limit of vulnerability can accurately predict the defibrillation threshold in patients undergoing implant...

متن کامل

Relation between upper limit of vulnerability and defibrillation threshold in humans.

BACKGROUND In the canine model, an upper limit of shock strength exists that can induce ventricular fibrillation during the vulnerable period of the cardiac cycle. This shock strength (the upper limit of vulnerability) closely correlates with the defibrillation threshold and supports the "upper limit of vulnerability" hypothesis of defibrillation. It is not known whether an upper limit of vulne...

متن کامل

Comparison of the defibrillation threshold and the upper limit of ventricular vulnerability.

To examine the relationship between the defibrillation threshold and the strength of shocks that induce ventricular fibrillation during the vulnerable period, we determined the defibrillation threshold in 22 open-chest dogs using epicardial defibrillation electrodes with the cathode at the ventricular apex and the anode at the right atrium. We also determined whether there was an upper limit of...

متن کامل

Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).

BACKGROUND Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduc...

متن کامل

Optical mapping of ventricular defibrillation in isolated swine right ventricles: demonstration of a postshock isoelectric window after near-threshold defibrillation shocks.

BACKGROUND Investigators who studied ventricular defibrillation by use of optical mapping techniques failed to observe an initial defibrillation event (isoelectric window or quiescent period) shown by electrode mapping studies. This discrepancy has important implications for the mechanisms of defibrillation. The purpose of the present study was to demonstrate an optical equivalent of an isoelec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 90 5  شماره 

صفحات  -

تاریخ انتشار 1994