Effects of a Harmonic Cavity at the Esrf
نویسندگان
چکیده
The installation of a harmonic cavity to provide bunch lengthening and thereby increase the Touschek lifetime is considered for the ESRF storage ring. Simulations with a particle tracking code have shown that for few bunch operation where the current per bunch is large – a strong lengthening already results from the coupling with the broad band impedance of the vacuum chamber. Therefore the net gain with an additional harmonic cavity is only moderate. For multibunch operation, however, where the current per bunch is small, a harmonic cavity is expected to increase the bunch length by up to a factor six, with a corresponding increase in Touschek lifetime. The Landau damping provided by the additional nonlinearity of the RF voltage has also been studied in detail. As an important and somewhat surprising result, it turns out that the thresholds for longitudinal coupled bunch instabilities may even be reduced when the operation parameters of the harmonic cavity are optimised to provide a maximum bunch lengthening.
منابع مشابه
Numerical study of a combined convection flow in a cavity filled with nanofluid considering effects of diameter of nanoparticles and cavity inclination angles
The present paper focuses on problem of mixed convection fluid flow and heat transfer of Al2O3-water nanofluid with temperature and nanoparticles concentration dependent thermal conductivity and effective viscosity inside Lid-driven cavity having a hot rectangular obstacle. The governing equations are discretized using the finite volume method while the SIMPLER algorithm is employed to couple v...
متن کاملAn Intelligent Method Based on WNN for Estimating Voltage Harmonic Waveforms of Non-monitored Sensitive Loads in Distribution Network
An intelligent method based on wavelet neural network (WNN) is presented in this study to estimate voltage harmonic distortion waveforms at a non-monitored sensitive load. Voltage harmonics are considered as the main type of waveform distortion in the power quality approach. To detect and analyze voltage harmonics, it is not economical to install power quality monitors (PQMs) at all buses. The ...
متن کاملInterference effects in second-harmonic generation within an optical cavity
An experiment is described that investigates certain interference effects for second-harmonic generation within a resonant cavity. By employing a noncollinear geometry, the phases of two fundamental beams from a frequencystabilized dye laser can be controlled unrestricted by the boundary conditions imposed in an optical cavity containing a KDP crystal and resonant at the second harmonic. The fu...
متن کاملHarmonic Modeling of Inrush Current in Core Type Power Transformers Using Hartley Transform
This paper presents a new method for evaluation and simulation of inrush current in various transformers using operational matrices and Hartley transform. Unlike most of the previous works, time and frequency domain calculations are conducted simultaneously. Mathematical equations are first represented to compute the inrush current based on reiteration and then Hartley transform is used to stud...
متن کاملGravity acceleration at the sea surface derived from satellite altimetry data using harmonic splines
Gravity acceleration data have grand pursuit for marine applications. Due to environmental effects, marine gravity observations always hold a high noise level. In this paper, we propose an approach to produce marine gravity data using satellite altimetry, high-resolution geopotential models and harmonic splines. On the one hand, harmonic spline functions have great capability for local gravity ...