Fast analysis of 29 polycyclic aromatic hydrocarbons (PAHs) and nitro-PAHs with ultra-high performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry

نویسندگان

  • Shih-Chun Candice Lung
  • Chun-Hu Liu
چکیده

Polycyclic aromatic hydrocarbons (PAHs) and nitro-PAHs are ubiquitous in the environment. Some of them are probable carcinogens and some are source markers. This work presents an ultra-high performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry (UHPLC-APPI-MS/MS) method for simultaneous analysis of 20 PAHs and nine nitro-PAHs. These compounds are separated in 15 minutes in the positive mode and 11 minutes in the negative mode, one half of GC/MS analysis time. Two pairs of precursor/product ions are offered, which is essential for confirmation. This method separates and quantifies benzo[a]pyrene (the most toxic PAHs) and non-priority benzo[e]pyrene (isomers, little toxicity) to avoid overestimation of toxin levels, demonstrating its importance for health-related researches. With 0.5% 2,4-difluoroanisole in chlorobenzene as the dopant, limits of detection of PAHs except acenaphthylene and those of nitro-PAHs except 2-nitrofluoranthene are below 10 pg and 3 pg, respectively, mostly lower than or comparable to those reported using LC-related systems. The responses were linear over two orders of magnitude with fairly good accuracy and precision. Certified reference materials and real aerosol samples were analyzed to demonstrate its applicability. This fast, sensitive, and reliable method is the first UHPLC-APPI-MS/MS method capable of simultaneously analyzing 29 environmentally and toxicologically important PAHs and nitro-PAHs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Determination of polycyclic aromatic hydrocarbons in sediment by liquid chromatography-atmospheric pressure photoionization-mass spectrometry.

We describe a method for the simultaneous determination of 12 kinds of polycyclic aromatic hydrocarbons (PAHs) in sediment based on liquid chromatography-atmospheric pressure photoionization-mass spectrometry (LC/APPI/MS). The method consists of PAH extractions by ultrasonics, clean-up by a solid-phase extraction procedure and determination by LC/APPI/MS. The limits of the determination for PAH...

متن کامل

The potential of low temperature extraction method for analysis of polycyclic aromatic hydrocarbons in refined olive and refined pomace olive oils by HPLC/FLD

Background and Objectives: A method was developed and validated for determining 15 polycyclic aromatic hydrocarbons (PAHs) in refined olive and refined pomace olive oils using high performance liquid chromatography coupled with a fluorescence detector. Materials and Methods: The sample preparation involved liquid–liquid extraction with organic solvent and low temperature clean-up. The low temp...

متن کامل

Liquid chromatography-atmospheric pressure laser ionization-mass spectrometry (LC-APLI-MS) analysis of polycyclic aromatic hydrocarbons with 6-8 rings in the environment.

A method has been developed for the sensitive and rapid analysis of polycyclic aromatic hydrocarbons (PAHs) in environmental samples using liquid chromatography time-of-flight mass spectrometry as well as the selective atmospheric pressure laser ionization (APLI) process (LC-APLI-MS). Upon analyzing 34 PAHs, the limits of detection of this method were found to range from 0.008 to 1.824 pg (0.02...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015