Factors Affecting Hemodialysis Adequacy in Cohort of Iranian Patient with End Stage Renal Disease

نویسندگان

  • Hosein Shahdadi
  • Abbas Balouchi
  • Zahra Sepehri
  • Hosein Rafiemanesh
  • Awad Magbri
  • Fereshteh Keikhaie
  • Ahmad Shahakzehi
  • Azizullah Arbabi Sarjou
چکیده

BACKGROUND There are many factors that can affect dialysis adequacy; such as the type of vascular access, filter type, device used, and the dose, and rout of erythropoietin stimulation agents (ESA) used. The aim of this study was investigating factors affecting Hemodialysis adequacy in cohort of Iranian patient with end stage renal disease (ESRD). METHODS This is a cross-sectional study conducted on 133 Hemodialysis patients referred to two dialysis units in Sistan-Baluchistan province in the cities of Zabol and Iranshahr, Iran. We have looked at, (the effects of the type of vascular access, the filter type, the device used, and the dose, route of delivery, and the type of ESA used) on Hemodialysis adequacy. Dialysis adequacy was calculated using kt/v formula, two-part information questionnaire including demographic data which also including access type, filter type, device used for hemodialysis (HD), type of Eprex injection, route of administration, blood groups and hemoglobin response to ESA were utilized. The data was analyzed using the SPSS v16 statistical software. Descriptive statistical methods, Mann-Whitney statistical test, and multiple regressions were used when applicable. RESULTS The range of calculated dialysis adequacy is 0.28 to 2.39 (units of adequacy of dialysis). 76.7% of patients are being dialyzed via AVF and 23.3% of patients used central venous catheters (CVC). There was no statistical significant difference between dialysis adequacy, vascular access type, device used for HD (Fresenius and B. Braun), and the filter used for HD (p> 0.05). However, a significant difference was observed between the adequacy of dialysis and Eprex injection and patients' time of dialysis (p <0.05). CONCLUSION Subcutaneous ESA (Eprex) injection and dialysis shift (being dialyzed in the morning) can have positive impact on dialysis adequacy. Patients should be educated on the facts that the type of device used for HD and the vascular access used has no significant effects on dialysis adequacy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Antitetanus Toxoid Antibody Titer of Chronic Hemodialysis Patients in Iran

Background: Patients with end stage renal disease have higher incidence of infection dis-eases that is thought to be related to impaired immune system. Objective: To determine the antitetanus IgG antibody level in Iranian hemodialysis patients with end stage renal disease and to find its association with sex, age, blood hemoglobin, serum albumin, dura-tion of dialysis, time of dialysis per week...

متن کامل

Avoidance of Dialysis in an End-Stage Renal Disease Patient Status-post Off-pump Coronary Artery Bypass Grafting

Certain benefits are clearly associated with the use of off-pump coronary artery bypass grafting (CABG) as compared with the on-pump CABG. The superiority is more evident in patients with multiple co morbidities including renal failure.We reviewed the medical records of a 67-year-old male with a past medical history that was significant for multiple cardiovascular diseases and new-onset end-sta...

متن کامل

Antitetanus toxoid antibody titer of chronic hemodialysis patients in Iran.

BACKGROUND Patients with end stage renal disease have higher incidence of infection diseases that is thought to be related to impaired immune system. OBJECTIVE To determine the antitetanus IgG antibody level in Iranian hemodialysis patients with end stage renal disease and to find its association with sex, age, blood hemoglobin, serum albumin, duration of dialysis, time of dialysis per week, ...

متن کامل

Factors Associated with Uremic Pruritus in Patients Undergoing Hemodialysis: A report from Arak Valiasr Hospital

Background: Pruritus is one of the most disabling problems in patients with chronic renal failure. It is a distressing symptom with a negative impact on quality of life and is also very frustrating for both patients and their physicians. The pathophysiological mechanisms of pruritus are mainly unknown. The aim of this study was to identify factors associated with pruritus in these patients. Met...

متن کامل

Dentomaxillofacial Radiographic Changes in a Group of Iranian Patients with End Stage Renal Disease Undergoing Hemodialysis

Introduction: This study aims to evaluate the dentomaxillofacial radiographic changes in end stage renal disease (ESRD) patients who were on hemodialysis. Methods: Parathyroid hormone (PTH), calcium, phosphorus and alkaline phosphatase (ALP) measurements, as well as Panoramic and periapical radiographs were obtained from seventy four patients with a history of end stage renal disease (ESRD). Re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2016