Surgical Results of Symmetric and Asymmetric Surgeries and Dose-Response in Patients with Infantile Esotropia
نویسندگان
چکیده
OBJECTIVES To evaluate the results of symmetric and asymmetric surgery and responses to surgical amounts in patients with infantile esotropia. MATERIALS AND METHODS The records of patients with infantile esotropia who underwent bilateral medial rectus recession (symmetric surgery) and unilateral medial rectus recession with lateral rectus resection (asymmetric surgery) were analyzed. The results of the cases with symmetric (group 1) and asymmetric (group 2), successful (group 3) and failed (group 4) surgeries were compared, and responses to the amount of surgery were investigated. RESULTS There were no significant differences between group 1 (n=71) and group 2 (n=13) cases in terms of gender, refraction, preoperative distance deviation, anisometropia and postoperative deviation angles, binocular vision, surgical success or follow-up period (p>0.05). The rate of amblyopia, near deviation and amount of surgery were higher in group 2 cases (p<0.05). Between group 3 (n=64) and group 4 subjects (n=20), no significant differences were detected in terms of gender, surgical age, refraction, amblyopia, anisometropia, preoperative deviation angles, the number of symmetric and asymmetric surgeries, the amount of surgery, or postoperative binocular vision (p>0.05). The average postoperative follow-up period was 15.41±19.93 months (range, 6-98 months) in group 3 cases and 40.45±40.06 months (range, 6-143 months) in group 4 cases (p=0.000). No significant difference was detected in the amount of deviation corrected per 1 mm of surgical procedure between the successful cases in the symmetric and asymmetric groups (p>0.05). CONCLUSION Symmetric or asymmetric surgery may be preferable in patients with infantile esotropia according to the clinical features. It is necessary for every clinic to review its own dose-response results.
منابع مشابه
A prospective study of alternating occlusion prior to surgical alignment for infantile esotropia: one-year postoperative motor results.
PURPOSE Alternating occlusion prior to surgical alignment has been suggested by some strabismologists to possibly enhance the treatment of infantile esotropia. This report presents the data for 44 patients prospectively enrolled by random assignment to an alternating occlusion or no occlusion subgroup followed for 1 year postoperatively. METHODS All patients were measured at entry into the st...
متن کاملBimedial rectus muscle elongation versus bimedial rectus muscle recession for the surgical treatment of large-angle infantile esotropia
PURPOSE To compare bimedial rectus muscle recession (BMRR; 7-8 mm) and bimedial rectus muscle elongation (BMRE; 6.5-9 mm) for the surgical treatment of large-angle infantile esotropia (ET; ≥70 prism diopters [PD]). PATIENTS AND METHODS Twenty-four patients with large-angle infantile ET were divided into 2 groups; group A (n=12) underwent BMRR and group B (n=12) underwent BMRE. All patients re...
متن کاملDirection-of-motion detection and motion VEP asymmetries in normal children and children with infantile esotropia.
PURPOSE To investigate nasal-temporal asymmetries in the detection of horizontal motion and in cortical motion visual evoked potential (mVEP) responses in normal infants and children and in patients with infantile esotropia. METHODS Monocular motion-detection thresholds were obtained separately for nasalward- and temporalward-moving random-dot patterns in a forced-choice, preferential-looking...
متن کاملAccuracy Evaluation of Isogray TPS Dose Calculations in Symmetric and Asymmetric Fields of the Elekta Compact Linear Accelerator
Introduction: Radiation therapy is one of the most important methods of cancer treatment. Radiation therapy uses symmetric and asymmetric fields in which the radiation dose distribution is different. To calculate the dose distribution, computer treatment planning systems are used which must have acceptable calculations accuracy. The aim of this study was to investigate the accuracy of the dose ...
متن کاملDosimetric evaluation of a treatment planning system using pencil beam convolution algorithm for enhanced dynamic wedges with symmetric and asymmetric fields
Background: The dosimetric performance of Eclipse 6.5 three dimensional treatment planning system (3DTPS) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of American Association for Physicists in Medicine Task Group 53. Materials and Methods: The calculations were performed by the 3DTPS for symmetric as well as asymmetric fields for standar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 45 شماره
صفحات -
تاریخ انتشار 2015