Multiple Site Fracture of Both Rods in a Malleable Penile Implant

نویسندگان

  • Marcelo Almeida Pinheiro
  • Haroldo Brasil Barroso Filho
  • Francisco José Cabral Mesquita
  • Ivon Teixeira de Souza
  • Rafael Silva Guimarães
  • Everaldo Moura Santos
  • Rômulo Augusto da Silveira
  • Rommel Prata Regadas
  • Geraldo Munguba Macedo
چکیده

Penile prosthesis implant is the definitive treatment for refractory erectile dysfunction. Fracture of malleable prosthesis is rarely described due to its low incidence. We describe a case of multiple, bilateral fracture of a malleable penile implant, ten years after implantation. After the diagnosis, a review surgery was performed and the implants were replaced. No corporal rupture or urethral lesion was observed. Review of the literature shows few articles reporting penile implant fractures, and to our knowledge no other article has described multiple, bilateral fractures of a penile prosthesis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Salvage penile prosthetic surgery utilizing temporary malleable implants

The inflatable penile prosthesis (IPP) is an effective erectile dysfunction (ED) treatment modality when oral and injectable therapies fail to achieve satisfactory results. Unfortunately, infection of the prosthetic remains a dreaded complication occurring in a small fraction of patients despite advances in device design and surgical techniques. With a prosthetic infection or erosion, classic m...

متن کامل

Pararectal Migration of a Malleable Rod: An Unusual Late Complication

A 75-year-old male had failed to respond conservative therapy for erectile dysfunction and had undergone insertion of a malleable penile prosthesis in 1995. Twenty years after the initial implant he presented with right-sided prosthesis localized in the buttock. There was no infection. The prosthesis was extracted through an incision in the right hip. As in the recent case, mechanical failures ...

متن کامل

Implant Failure of Titanium Versus Cobalt-Chromium Growing Rods in Early-onset Scoliosis.

STUDY DESIGN Retrospective case series of one institute database. OBJECTIVE To investigate the differences in the metallic strength of rods used for implant failure in the dual growing rod technique and evaluate clinical outcomes. SUMMARY OF BACKGROUND DATA The dual growing rod technique in which implanted rods extend with the growth of the spine is a useful treatment for early onset scolio...

متن کامل

Infrapubic approach for malleable penile implant.

PURPOSE Today, we find that the implant of malleable prostheses still plays a leading role in the surgical treatment of erectile dysfunction. These may involve patients for which the cosmetic advantages of inflatable devices are not as important as low cost, the easier use and less incidence of mechanical complications in the malleable implants. This paper demonstrates infrapubic approach as a ...

متن کامل

Penile prosthesis implant: scientific advances and technological innovations over the last four decades

Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016