[Optimization of X-ray conditions for full spine X-ray examinations in slot-scan digital radiography].

نویسندگان

  • Kimiya Noto
  • Syuhei Minami
  • Ayumi Morishita
  • Tomohiro Yokoi
  • Hiroji Iida
  • Kosuke Matsubara
  • Akihiro Takemura
  • Kichiro Koshida
چکیده

The purpose of this study was to optimize X-ray conditions for full spine X-ray examinations in slot-scan digital radiography (SSDR). Follow-up of spinal deformities, such as scoliosis, typically involves many radiographs of the patient throughout childhood and adolescence. The Radiation doses for the full spine X-ray examination should be minimized. Recently, SSDR has been introduced for full spine as well as lower extremity examinations. This system utilizes slot scanning geometry to acquire the radiographic images. X-ray energy characteristics of direct amorphous Selenium (a-Se) digital fluoroscopy and short time X-ray tube loads of this system were investigated. Orthopedists evaluated the irradiation time for full spine radiographs in various conditions using an observer study. Patient doses were measured with radiophotoluminescence glass dosimeters, which were implanted in various tissue and organ positions within an anthropomorphic phantom. In the optimization of conditions for SSDR, patient doses are reduced by approximately 60% compared to default setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Paediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran

Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. <...

متن کامل

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...

متن کامل

Local-Reference Patient Dose Evaluation in Conventional Radiography Examinations in Mazandaran, Iran

Background:The most efficient application of ionizing radiation is serving medical purposes and using this radiation has caused people to learn that artificial sources of radiation exposure among these resources can be of highest exposure rate.  Objective: The present study is aimed at initially establishing a baseline for local-reference dose level in Mazandaran, Iran in 12 projections of the...

متن کامل

Optimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations

IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...

متن کامل

Accuracy Assessment of Ultrasonic C-scan and X-ray Radiography Methods for Impact Damage Detection in Glass Fiber Reinforced Polyester Composites

The present study introduces two quantitative parameters to compare the accuracy of ultrasonic C-scan testing and X-ray radiography methods in the damaged area detection under low-velocity impact in polymer-based composites. For this purpose, the hand lay-up technique of composite processing was employed to prepare the composite specimen. A composite specimen consisting of the glass fiber reinf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon Hoshasen Gijutsu Gakkai zasshi

دوره 67 11  شماره 

صفحات  -

تاریخ انتشار 2011