Indirect determination of trace amounts of fluoride in natural waters by ion chromatography: a comparison of on-line post-column fluorimetry and ICP-MS detectors.

نویسندگان

  • M M Bayón
  • A Rodríguez Garcia
  • J I García Alonso
  • A Sanz-Medel
چکیده

An alternative method for the determination of trace levels of fluoride in drinking and sea-water samples is presented. It is based on the formation of the aluminium monofluoride complex in excess of Al3+ and separation of the two species formed (AlF2+ and Al3+) in a small (5 cm long, CG2) ion exchange guard column. The final determination is accomplished by both ICP-MS specific detection and post column derivatisation with fluorimetric detection. Fundamental studies on the formation kinetics of the complex, ion chromatographic separation and optimum aluminium concentration were carried out using spectrofluorimetric detection by post-column reaction of the species with 8-hydroxyquinoline-5-sulfonic acid in a micellar medium of cetyltrimethylammonium bromide. Fluorimetric detection showed good detection limits, but interferences from cations such as Mg2+ and Zn2+ required the use of the longer CS2 ion exchange column. Iron interfered in relatively large amounts but adding EDTA to the sample solution eliminated the interference. A similar separation methodology was applied using ICP-MS detection for the indirect determination of fluoride, by monitoring aluminium at mass 27. In this case, a detection limit of 0.1 ng ml-1 was obtained using 0.45 M HNO3 as eluent and no interference caused by high concentrations of iron was observed. The proposed method was applied to the determination of very low levels of fluoride in natural waters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Fluoride in the Bottled Drinking Waters in Iran

Fluoride is recognized as an effective agent for dental caries prevention. Generally, the main source of fluoride intake is drinking water. In this study, fluoride content in 18 commercial brands of bottled waters was investigated. Six samples from each batch of 18 Iranian commercial brands of bottled waters were supplied. The fluoride content of samples was analyzed by Fluoride Ion Selective E...

متن کامل

Determination of Fluoride in the Bottled Drinking Waters in Iran

Fluoride is recognized as an effective agent for dental caries prevention. Generally, the main source of fluoride intake is drinking water. In this study, fluoride content in 18 commercial brands of bottled waters was investigated. Six samples from each batch of 18 Iranian commercial brands of bottled waters were supplied. The fluoride content of samples was analyzed by Fluoride Ion Selective E...

متن کامل

Determination of iopromide in environmental waters by ion chromatography - ICP - MS

The determination of iopromide in environmental waters has been accomplished using an Agilent 7700x ICP-MS coupled to an Agilent 1260 LC. The use of High Matrix Introduction (HMI) technology allows for prolonged operation with a sodium hydroxide (NaOH) eluent, and the Octopole Reaction System (ORS3) in helium gas mode reduces polyatomic interferences on iodine (m/z 127). Determination of ioprom...

متن کامل

Kinetic spectrophotometric determination of trace amounts of nitrite ion using potassium bromate-murexide mixture in acidic media

A new, simple, rapid, and cheap method for determination of trace amounts of nitrite ion is reported.Determination is based on reduction of bromate ion by nitrite ion, in the presence of murexide inacidic media. During reaction of bromate ion with nitrite ion, the reaction mixture is decolorized.The absorbance changes is then monitored spectrophotometricaly at 520 nm, at 25 °C. Dynamicrange of ...

متن کامل

Extraction-Fluorimetric Determination of Trace Amounts of Mercury by 1,10-Diaza-18-Crown-6 and Rose Bengal

A simple and sensitive extraction-fluorimetric method for the determination of mercury is reported. The method is based on the quantitative extractionof a ternary crown-mercury-rose Bengal complex into chloroform at pH 10 followed by fluorimetric measurements at 580 nm. A linear working range from 0.05 to 2.00 mg/mL is obtained. The relative standard deviation for 1.0 </em...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 124 1  شماره 

صفحات  -

تاریخ انتشار 1999