Evaluation of a research use only luminex based assay for measurement of procalcitonin in serum samples.

نویسندگان

  • Charles Garrigan
  • Jennifer Han
  • Pam Tolomeo
  • Katherine J Johnson
  • Stephen R Master
  • Ebbing Lautenbach
  • Irving Nachamkin
چکیده

Research use only (RUO) assays do not undergo a validation process similar to test kits used for clinical purposes. Several studies have suggested that RUO assays need to be validated prior to use in any research studies. We evaluated a research use only Luminex platform based assay for measuring serum procalcitonin levels (Bio-Plex ProTM Human Acute Phase Multiplex Assay, Bio-Rad Laboratories, Hercules, CA) for comparability with an FDA cleared assay for procalcitonin (VIDAS B.R.A.H.M.S. PCT Assay, bioMérieux, Durham, NC). We tested 1,072 serum samples collected from patients with suspected sepsis in an intensive care unit setting for the comparison. There was poor correlation of the luminex based assay (r=0.081) with the VIDAS PCT Assay in the clinically relevant measurement range (<10 ng/mL). Additionally the Bio-Plex assay showed poor precision. Mass-spectrometry analysis of material eluted from PCT beads did not reveal any identifiable procalcitonin. The results show that research use only assays need to be validated to determine their suitability for research studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Significance of Serum Procalcitonin Level in the Early Diagnosis of Neonatal Sepsis

Background: Sepsis in neonates presents itself with non-specific clinical features which makes early diagnosis difficult. However, procalcitonin (PCT) and other inflammatory markers have recently been considered as sensitive markers for the early detection of neonatal sepsis. Therefore, the present study aimed to determine the diagnostic value of PCT in the early detection of neonatal sepsis an...

متن کامل

Evaluation of procalcitonin as a biomarker of diagnosis, severity and postoperative complications in adult patients with acute appendicitis

  Background :Delay in diagnosis and treatment of acute appendicitis (AA) results in an increased rate of perforation, postoperative morbidity, mortality and hospital length of stay. Several biochemical parameters including white blood cell (WBC) count, C-reactive protein (CRP), interleukin-6 (IL6) and Procalcitonin (PCT) have been used to further improve the clinical diagnosis of AA. The aim o...

متن کامل

The Comparison of the Point-of-Care Serum Procalcitonin Assay Method with the BRAHMS Certified Method

Background and Aims: As a method for the diagnosis and management of sepsis, the serum procalcitonin assay is routinely used, especially in the emergency department (ED) and intensive care units (ICU). Procalcitonin has reasonable diagnostic accuracy for bacteremia in hospitalized patients of all age groups with suspected infection or sepsis. This study aimed to compare the Getein Biotech proca...

متن کامل

اندازه گیری سطح سرمی پروکلسی‌تونین در بیماران مشکوک به آنفولانزای خوکی (H1N1)

Abstract Background: Measurement of serum level of procalcitonin in patients with H1N1 influenza could decrease the consumption of unnecessary antibiotics. This study aimed to determine the serum levels of procalcitonin in patients with swine flu (H1N1) in the Hajar Hospital of Shahrekord in 2011. Materials and Methods: In this cross-sectional study patients presenting with clinical manifestati...

متن کامل

The Evaluation of Serum Procalcitonin Levels in Neonatal Infections

Background Procalcitonin is known as one of the bacteremia and sepsis markers such as cytokines, interleukin and reactive proteins. This study was conducted to determine the procalcitonin levels in neonatal sepsis. Materials and Methods In a cross-sectional study, the serum procalcitonin levels in 50 term newborns with suspected sepsis was compared with 50 healthy newborns in Ghaem Hospital, Ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of translational research

دوره 8 10  شماره 

صفحات  -

تاریخ انتشار 2016