Method for verifying the air kerma strength of I‐125 plaques for the treatment of ocular melanoma
نویسندگان
چکیده
The purpose of this work was to develop a method for easily verifying that the activity or air kerma strength of pre-assembled eye plaques, used in the treatment of ocular melanomas, agrees with the activity or air kerma strength called for in the treatment plan. A Capintec CRC-7 Dose Calibrator with its standard vial/syringe sample holder was used to measure the activity of pre-assembled COMS and Eye Physics EP917 eye plaques using IsoAid Advantage I-125 seeds. Plaque activity measurements were made by placing the plaque face up in the center of a 5 cm tall Styrofoam insert in the source holder. Activity measurements were made with the source holder rotated to four angles (0°, 90°, 180°, and 270°). The average of these four values was converted to air kerma strength and divided by the assay air kerma strength, from the NIST traceable source calibration, and decayed to the plaque measurement date, to determine a plaque calibration factor. The average of the calibration factors for each plaque type was used to establish a calibration factor for each plaque type. Several partially loaded plaque configurations were included in this study and different methods were used to determine the effects of partial loading. This verification method is easy to implement with commonly available equipment and is effective in identifying possible errors. During this two-year study, the air kerma strength of 115 eye plaques was checked and 11 possible errors were identified.
منابع مشابه
Dosimetric benefit of a new ophthalmic radiation plaque.
PURPOSE To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. METHODS AND MATERIALS One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in ...
متن کاملSilastic Thickness Optimization in Uveal Melanoma Brachytherapy by Monte Carlo Method
Introduction In order to treat uveal Melanoma , first, radioactive seeds are laid on a silicone- made substance which is called Silastic after that they are inserted in the plaque, and finally, this plaque containing silicone-made substance is stitched to the sclera surface. The dose gradient within the tumor and healthy tissues can be varied due to changing the Silastic thickness between scler...
متن کاملDosimetric characteristics of 137Cs sources used in after loading Selectron system by Monte Carlo method
Background: For an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. The usual method to determine these factors is thermo luminescent dosimeter (TLD) dosimetry. Nowadays, another more accurate method is known to be the Monte Carlo ...
متن کاملDosimetric investigation of high dose rate Ir-192 source with Monte Carlo method
Background: This study aims to calculate the air-kerma strength (SK), the dose rate constant (∧) and the dose rate profiles of a Gammamed 12i Ir-192 source by using the Monte Carlo technique and to compare the dose rate values with those calculated by the Abacus HDR treatment planning system (TPS). Materials and Methods: Air-kerma strength (in units of U; 1 U= μGy m2 h-1) and the dose ra...
متن کاملMonte Carlo Simulation for Treatment Planning Optimization of the COMS and USC Eye Plaques Using the MCNP4C Code
Introduction: Ophthalmic plaque radiotherapy using I-125 radioactive seeds in removable episcleral plaques is often used in management of ophthalmic tumors. Radioactive seeds are fixed in a gold bowl-shaped plaque and the plaque is sutured to the scleral surface corresponding to the base of the intraocular tumor. This treatment allows for a localized radiation dose delivery to the tumor with a ...