Addendum to brachytherapy dose‐volume histogram commissioning with multiple planning systems
نویسنده
چکیده
The process for validating dose-volume histogram data in brachytherapy software is presented as a supplement to a previously published article. Included is the DVH accuracy evaluation of the Best NOMOS treatment planning system called "Best TPS VolumePlan." As done previously in other software, a rectangular cuboid was contoured in the treatment planning system. A single radioactive 125I source was positioned coplanar and concentric with one end. Calculations were performed to estimate dose deposition in partial volumes of the cuboid structure, using the brachytherapy dosimetry formalism defined in AAPM Task Group 43. Hand-calculated, dose-volume results were compared to TPS-generated, point-source-approximated dose-volume histogram data to establish acceptance. The required QA for commissioning was satisfied for the DVH as conducted previously for other software, using the criterion that the DVH %VolTPS "actual variance" calculations should differ by no more than 5% at any specific radial distance with respect to %VolTG-43, and the "average variance" DVH %VolTPS calculations should differ by no more than 2% over all radial distances with respect to %VolTG-43. The average disagreement observed between hand calculations and treatment planning system DVH was less than 0.5% on average for this treatment planning system and less than 1.1% maximally for 1 ≤ r ≤ 5 cm.
منابع مشابه
Brachytherapy dose‐volume histogram commissioning with multiple planning systems
The first quality assurance process for validating dose-volume histogram data involving brachytherapy procedures in radiation therapy is presented. The process is demonstrated using both low dose-rate and high dose-rate radionuclide sources. A rectangular cuboid was contoured in five commercially available brachytherapy treatment planning systems. A single radioactive source commissioned for QA...
متن کاملQuality assurance procedures during commissioning of a treatment planning system as a tool to establish new standards before migration
PURPOSE Treatment planning system commissioning is one of the most important parts of the quality assurance system in a working brachytherapy department. Migration to a more sophisticated system is always a step forward for the planning team but careful verification of the workflow and obtained results is mandatory. The question is not only whether the quality and safety of the previous standar...
متن کاملThe Role of Computed Tomography Based Treatment Planning in High Dose Rate (hdr) Brachytherapy in Carcinoma of the Cervix
Aim: To compare the high dose rate (HDR) brachytherapy treatment planning using standard orthogonal radiography and computerized tomography (CT) for carcinoma of the cervix. Methods: Forty applications with orthogonal planning using the Brachy Vision treatment planning system version 7.3.10 were performed. Orthogonal and CT based planning in these applications were compared; the doses to point ...
متن کاملDose volume uniformity index: a simple tool for treatment plan evaluation in brachytherapy
PURPOSE In radiotherapy treatment planning, dose homogeneity inside the target volume plays a significant role in the final treatment outcome. Especially in brachytherapy where there is a steep dose gradient in the dose distribution inside the target volume, comparing the plans based on the dose homogeneity helps in assessing the high dose volume inside the final treatment plan. In brachytherap...
متن کاملA study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy
Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...
متن کامل