Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switching.

نویسندگان

  • Bruno Andrade Cantharino de Carvalho
  • Eduardo Vedovatto
  • Paulo Sérgio Perri de Carvalho
  • José Vitor Quinelli Mazaro
  • Rosse Mary Falcón-Antenucci
چکیده

This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value

Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...

متن کامل

Influence of the ultimate torsion on the geometry of dental implants.

This study evaluated the profile of implants subjected to torsion test. Four types of implants (Conexão®) were analyzed: Master Porous (MP - external hexagon, cylindrical, double-porous surface implants; 11.5 X 3.75 mm), Master Screw (MS - external hexagon, cylindrical, machined implants; 11.5 X 3.75 mm), Conect Conic (CC - external hexagon, cylindrical, machined implants; 11.5 X 3.5 mm) and Ma...

متن کامل

Effect of GapSeal® as a Sealing Material on Microgap and Microleakage at External Hexagon Implant Connections Following Cyclic Loading: An In Vitro Study

Background and Aim: The mismatch of the implant-abutment connection can produce instant stress and microleakage which result in mechanical and biological complications. This study aimed to investigate the influence of GapSeal® as a sealing material on the extent of microgap and microleakage at the external hexagon implant platform following cyclic loading. Materials and Methods: Sixteen implan...

متن کامل

Stability of external and internal implant connections after a fatigue test

OBJECTIVE The objective of this study was to compare the torque and detorque values of screw intermediates of external hexagon, internal hexagon, and Morse taper implants in single restorations before and after mechanical cycling. MATERIALS AND METHODS The study sample was divided into three groups (n = 10) as follows: group EH - external hexagon implant, group IH - internal hexagon implant, ...

متن کامل

Evaluation of the External Hexagon Dental Implants after Simulating Surgical Placement and the Rotational Freedom of Implant Components

Currently, there are several possibilities of abutments connections in dental implants. The most common design in use is the external hexagon connection, which, besides the function of transmitting torque at surgical placement, also works as an antirotational mechanism and orientation of the abutment for single tooth prostheses. Several researchers have suggested that screw joint stability is d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Brazilian dental journal

دوره 26 3  شماره 

صفحات  -

تاریخ انتشار 2015