Resolution of pulmonary multiplanar reconstruction images from 0.5-mm theoretical isotropic data: a fundamental study using an inflated and fixed lung specimen.
نویسندگان
چکیده
The aim of the present study was to define the resolution of multiplanar reconstruction (MPR) of the lung from "theoretical isotropic data." Using inflated and fixed lung specimens of the pig placed in the chest wall phantom, 0.5-mm isotropic data were obtained with 2 different helical pitches: 1:7 (high-quality mode) or 1:13, (high-speed mode), and 2 different tube currents: 250 mAs (high-tube-current mode) or 100 mAs (low-tube-current mode), with or without overlapping reconstruction. MPRs were created from these axial data. The diameter of the smallest visible pulmonary artery and bronchi of these CT images were measured on the corresponding slices of the specimen. The high-speed and low-tube-current mode significantly degraded the image quality due to increased noise. The smallest visible pulmonary artery and bronchus resolved on MPRs from axial-spiral data with 0.5-mm collimation were approximately 100 micrometer and 1,000 micrometer in diameter, respectively. In conclusion, helical pitch and tube current influence the resolution of MPR of the lung.
منابع مشابه
بررسی دقت سیتیاسکن اسپیرال با بازسازی به روش Multi Planar(MPR) در اندازهگیری طول کلیه در بیمارستان شهید هاشمینژاد در سال 1383
Background & Aim: Measuring the length of kidneys is an important issue in diagnosis and treatment of renal diseases. In various diseases, kidneys become larger or smaller than normal. Ultrasonography is a suitable method for measuring renal length because it is accurate, noninvasive, available and with low cost. Nowadays, multislice spiral CT scanners are widely used for evaluation of rena...
متن کاملCollimator-detector response compensation in molecular SPECT reconstruction using STIR framework
Introduction:It is well-recognized that collimator-detector response (CDR) is the main image blurring factor in SPECT. In this research, we compensated the images for CDR in molecular SPECT by using STIR reconstruction framework. Methods: To assess resolution recovery capability of the STIR, a phantom containing five point sources along with a micro Derenzo p...
متن کاملDetectability of Various Sizes of Honeycombing Cysts in an Inflated and Fixed Lung Specimen: the Effect of CT Section Thickness
OBJECTIVE We wanted to clarify the relationship between the visibility of air cysts on CT images, the CT slice thickness and the size of the air cysts, with contact radiographs as the gold standard, for the accurate evaluation of honeycomb cysts. MATERIALS AND METHODS An inflated and fixed autopsied lung having idiopathic interstitial pneumonia was evaluated. The corresponding air cysts were ...
متن کاملImpact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer
Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...
متن کاملImpact of Novel Incorporation of CT-based Segment Mapping into a Conjugated Gradient Algorithm on Bone SPECT Imaging: Fundamental Characteristics of a Context-specific Reconstruction Method
Objective(s): The latest single-photon emission computed tomography (SPECT)/computed tomography (CT) reconstruction system, referred to as xSPECT Bone™, is a context-specific reconstruction system utilizing tissue segmentation information from CT data, which is called a zone map. The aim of this study was to evaluate theeffects of zone-map enhancement incorporated into the ordered-subset conjug...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta medica Okayama
دوره 61 2 شماره
صفحات -
تاریخ انتشار 2007