Pathophysiology of Haemostasis and Thrombosis Preprint Copy The Extent of Platelet Activation under Shear Depends on Platelet Count: Differential Expression of Anionic Phospholipid and Factor Va

نویسندگان

  • Katherine Schulz-Heik
  • Jaimohan Ramachandran
  • Danny Bluestein
  • Jolyon Jesty
چکیده

It is widely accepted that shear stress activates platelets. However, this may have two linked but separate causes: a direct effect of shear stress on individual platelets, and secondary interplatelet activation dependent on the release of agonists caused by shear. Gel-filtered platelets were exposed to intermittent low shear at 20,000 plts/μl and 200,000 plts/μl and their activation was measured with a prothrombinase-based assay. At the lower count activation was slow and essentially linear, but at the higher count it rose exponentially with time, leading to 3-fold more prothrombinase activity. Inclusion of apyrase and/or prostaglandin I2 slightly reduced activation at high platelet counts, but did not abolish the nonlinear kinetics; and antibodies against von Willebrand factor had no significant effect. The contributions of anionic phospholipid and factor Va to the prothrombinase activity were assessed by measurements in the presence of exogenous factor Va. The results strongly suggest that anionic phospholipid appearance is directly caused by shear exposure, but that factor Va release from the α granules is a secondary event, and largely the result of platelet-platelet signaling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The extent of platelet activation under shear depends on platelet count: differential expression of anionic phospholipid and factor Va.

It is widely accepted that shear stress activates platelets. However, this may have two linked but separate causes: a direct effect of shear stress on individual platelets, and secondary inter-platelet activation dependent on the release of agonists caused by shear. Gel-filtered platelets were exposed to intermittent low shear at 20,000 and 200,000 platelets/microl and their activation was meas...

متن کامل

An Overview on Platelet-derived Microparticles in Platelet Concentrates: blood collection, method preparation and storage

Preparations of platelet concentrates (PCs) that are stored under blood bank conditions and used for transfusion purposes, appear to be enriched in platelet derived-microparticles (PMPs) with high coagulant activity that may change platelet efficacy and safety issues. High shear stress could cause shedding of PMPs from the platelet plasma membrane, platelet aggregation, and activation of the co...

متن کامل

Platelet activation and blood coagulation.

Platelet activation and blood coagulation are complementary, mutually dependent processes in haemostasis and thrombosis. Platelets interact with several coagulation factors, while the coagulation product thrombin is a potent platelet-activating agonist. Activated platelets come in a procoagulant state after a prolonged elevation in cytosolic [Ca2+]i. Such platelets, e.g. when adhering to collag...

متن کامل

Virchow's triad revisited: abnormal flow.

Virchow rightly recognised that blood flow plays an important role in thrombosis. The roles of blood flow in haemostasis, and in arterial, intra-cardiac, and venous thrombosis are reviewed. In streamline (laminar) flow, shear stresses are maximal at the vessel wall, and affect endothelial cell morphology and function (e.g. secretion of NO, prostacyclin,t-PA and vWF). Platelets are also concentr...

متن کامل

Effects of von Willebrand factor concentration and platelet collision on shear-induced platelet activation.

The binding of plasma von Willebrand factor (vWF) to platelet glycoprotein (GP) Ibalpha in a high shear stress field, and subsequent integrin-GPIIb/IIIa-vWF conjunction induces platelet aggregation (SIPA). However, the specific biomechanical mechanism of the vWF-GPIb interaction still remains to be elucidated. A parallel-plate rectangular flow chamber was built to simulate a stenopeic artery fl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006